Background: Hemodialysis is complicated by a high incidence of intradialytic hypotension and disequilibrium symptoms caused by hypovolemia and a decrease in extracellular osmolarity. Automatic adaptive system dialysis (AASD) is a proprietary dialysis system that provides automated elaboration of dialysate and ultrafiltration profiles based on the prescribed decrease in body weight and sodium content. Study Design: A noncontrolled (single arm), multicenter, prospective, clinical trial. Setting & Participants: 55 patients with intradialytic hypotension or disequilibrium syndrome in 15 dialysis units were studied over a 1-month interval using standard treatment (642 sessions) followed by 6 months using AASD (2,376 sessions). Intervention: AASD (bicarbonate dialysis with dialysate sodium concentration and ultrafiltration rate profiles determined by the automated procedure). Outcomes: Primary and major secondary outcomes were the frequency of intradialytic hypotension and symptoms (hypotensive events, headache, nausea, vomiting, and cramps), respectively. Results: More stable intradialytic systolic and diastolic blood pressures with lower heart rate were found using AASD compared with standard treatment. Sessions complicated by hypotension decreased from 58.7% +/- 7.3% to 0.9% +/- 0.6% (P < 0.001). The incidence of other disequilibrium syndrome symptoms was lower in patients receiving AASD. There were no differences in end-session body weight, interdialytic weight gain, or presession natremia between the standard and AASD treatment periods. Limitations: A noncontrolled (single arm) study, no crossover from AASD to standard treatment. Conclusions: This study shows the long-term clinical efficacy of AASD for intradialytic hypotension and disequilibrium symptoms in a large number of patients and dialysis sessions. Am J Kidney Dis. 58(1):93-100. (C) 2011 by the National Kidney Foundation, Inc.

Automatic Adaptive System Dialysis for Hemodialysis-Associated Hypotension and Intolerance: A Noncontrolled Multicenter Trial

PANICHI, VINCENZO;
2011-01-01

Abstract

Background: Hemodialysis is complicated by a high incidence of intradialytic hypotension and disequilibrium symptoms caused by hypovolemia and a decrease in extracellular osmolarity. Automatic adaptive system dialysis (AASD) is a proprietary dialysis system that provides automated elaboration of dialysate and ultrafiltration profiles based on the prescribed decrease in body weight and sodium content. Study Design: A noncontrolled (single arm), multicenter, prospective, clinical trial. Setting & Participants: 55 patients with intradialytic hypotension or disequilibrium syndrome in 15 dialysis units were studied over a 1-month interval using standard treatment (642 sessions) followed by 6 months using AASD (2,376 sessions). Intervention: AASD (bicarbonate dialysis with dialysate sodium concentration and ultrafiltration rate profiles determined by the automated procedure). Outcomes: Primary and major secondary outcomes were the frequency of intradialytic hypotension and symptoms (hypotensive events, headache, nausea, vomiting, and cramps), respectively. Results: More stable intradialytic systolic and diastolic blood pressures with lower heart rate were found using AASD compared with standard treatment. Sessions complicated by hypotension decreased from 58.7% +/- 7.3% to 0.9% +/- 0.6% (P < 0.001). The incidence of other disequilibrium syndrome symptoms was lower in patients receiving AASD. There were no differences in end-session body weight, interdialytic weight gain, or presession natremia between the standard and AASD treatment periods. Limitations: A noncontrolled (single arm) study, no crossover from AASD to standard treatment. Conclusions: This study shows the long-term clinical efficacy of AASD for intradialytic hypotension and disequilibrium symptoms in a large number of patients and dialysis sessions. Am J Kidney Dis. 58(1):93-100. (C) 2011 by the National Kidney Foundation, Inc.
2011
Coli, L; La Manna, G; Comai, G; Ursino, M; Ricci, D; Piccari, M; Locatelli, F; Di Filippo, S; Cristinelli, L; Bacchi, M; Balducci, A; Aucella, F; Panichi, Vincenzo; Ferrandello, Fp; Tarchini, R; Lambertini, D; Mura, C; Marinangeli, G; Di Loreto, E; Quarello, F; Forneris, G; Tancredi, M; Morosetti, M; Palombo, G; Di Luca, M; Martello, M; Emiliani, G; Bellazzi, R; Stefoni, S.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/151754
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 29
social impact