The study aimed to evaluate the reproducibility of carotid elasticity during exercise. Eighteen healthy volunteers (nine males, age 34 ± 3 years, BMI 22 ± 6 kg/m(2)) underwent maximal exercise testing on a graded semi-supine cycle ergometer in two different sessions 3 days apart. Ultrasound B-mode image sequences of the right common carotid were acquired at different steps and analyzed by an automatic system; pressures were estimated by tonometry. Compliance (CC) and distensibility (DC) were significantly decreased at exercise peak and in the first recovery minute (CC from 1.6 ± 0.8 to 1 ± 0.6 mm^(2)/KPa, DC from 56.2 ± 25.3 to 34.5 ± 20 10^(-3)/KPa, p < 0.05). For the whole examination, intraclass coefficient was 0.780 for CC and 0.694 for DC. Mean coefficient of variation was maximum at peak exercise (CC = 19 ± 6%, DC = 24 ± 15%), but at first minute of recovery it was comparable to resting values (CC = 12 ± 9%, DC = 12 ± 11%). When designing future studies, acquisitions during first recovery minute might be preferred to peak measures

Assessment of carotid elasticity during exercise: a reproducibility study.

BRUNO, ROSA MARIA;GHIADONI, LORENZO;
2012-01-01

Abstract

The study aimed to evaluate the reproducibility of carotid elasticity during exercise. Eighteen healthy volunteers (nine males, age 34 ± 3 years, BMI 22 ± 6 kg/m(2)) underwent maximal exercise testing on a graded semi-supine cycle ergometer in two different sessions 3 days apart. Ultrasound B-mode image sequences of the right common carotid were acquired at different steps and analyzed by an automatic system; pressures were estimated by tonometry. Compliance (CC) and distensibility (DC) were significantly decreased at exercise peak and in the first recovery minute (CC from 1.6 ± 0.8 to 1 ± 0.6 mm^(2)/KPa, DC from 56.2 ± 25.3 to 34.5 ± 20 10^(-3)/KPa, p < 0.05). For the whole examination, intraclass coefficient was 0.780 for CC and 0.694 for DC. Mean coefficient of variation was maximum at peak exercise (CC = 19 ± 6%, DC = 24 ± 15%), but at first minute of recovery it was comparable to resting values (CC = 12 ± 9%, DC = 12 ± 11%). When designing future studies, acquisitions during first recovery minute might be preferred to peak measures
2012
Bianchini, E; Bruno, ROSA MARIA; Corciu, Ai; Faita, F; Gemignani, V; Ghiadoni, Lorenzo; Picano, E; Sicari, R.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/156832
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 130
  • ???jsp.display-item.citation.isi??? 12
social impact