AimsThe paucity of evidences about the long-term durability of currently available transcatheter prostheses is one of the main issues of transcatheter aortic valve implantation (TAVI). We sought to assess 3-year clinical and echocardiographic outcomes of patients undergoing TAVI with the third generation CoreValve prosthesis (Medtronic Incorporation, MN, USA).Methods and resultsFrom the Italian CoreValve registry, 181 who underwent TAVI from June 2007 to August 2008 and eligible for 3-year follow-up were analysed. All outcomes were defined according to the Valve Academic Research Consortium. All-cause mortality at 1, 2, and 3 years was 23.6, 30.3, and 34.8%, respectively. Cardiovascular death at 1, 2, and 3 years was 11.2, 12.1, and 13.5%, respectively. The actuarial survival free from a composite of death, major stroke, myocardial infarction, and life-threatening bleeding was 69.6% at 1 year, 63.5% at 2 years, and 59.7% at 3 years. Patients with renal insufficiency had a higher mortality at 3-year follow-up (49.0 vs. 29.2%, P = 0.007); moreover, patients experiencing post-procedural major or life-threatening bleeding had a higher rate of mortality already seen at 30 days (21.6 vs. 2.8%; P < 0.001) and this result was sustained at 3-year follow-up (62.2 vs. 27.7%; P < 0.001). Mean pressure gradients decreased from 52.2 ± 18.1 mmHg (pre-TAVI) to 10.3 ± 3.1 mmHg (1-year post-TAVI) (P < 0.001); aortic valve area increased from 0.6 ± 0.2 cm(2) (pre-TAVI) to 1.8 ± 0.4 cm(2) (1-year post-TAVI); these results remained stable over the 3 years of follow-up. Paravalvular leak was observed in the majority of patients. There were no cases of progression to moderate or severe regurgitation. No cases of structural valve deterioration were observed.ConclusionThis multicentre study demonstrates that TAVI with the 18-Fr CoreValve ReValving System is associated with sustained clinical and functional cardiovascular benefits in high-risk patients with symptomatic aortic stenosis up to 3-year follow-up. Non-cardiac causes accounted for the majority of deaths at follow-up.

Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis.

PETRONIO, ANNA;De Carlo M;
2012-01-01

Abstract

AimsThe paucity of evidences about the long-term durability of currently available transcatheter prostheses is one of the main issues of transcatheter aortic valve implantation (TAVI). We sought to assess 3-year clinical and echocardiographic outcomes of patients undergoing TAVI with the third generation CoreValve prosthesis (Medtronic Incorporation, MN, USA).Methods and resultsFrom the Italian CoreValve registry, 181 who underwent TAVI from June 2007 to August 2008 and eligible for 3-year follow-up were analysed. All outcomes were defined according to the Valve Academic Research Consortium. All-cause mortality at 1, 2, and 3 years was 23.6, 30.3, and 34.8%, respectively. Cardiovascular death at 1, 2, and 3 years was 11.2, 12.1, and 13.5%, respectively. The actuarial survival free from a composite of death, major stroke, myocardial infarction, and life-threatening bleeding was 69.6% at 1 year, 63.5% at 2 years, and 59.7% at 3 years. Patients with renal insufficiency had a higher mortality at 3-year follow-up (49.0 vs. 29.2%, P = 0.007); moreover, patients experiencing post-procedural major or life-threatening bleeding had a higher rate of mortality already seen at 30 days (21.6 vs. 2.8%; P < 0.001) and this result was sustained at 3-year follow-up (62.2 vs. 27.7%; P < 0.001). Mean pressure gradients decreased from 52.2 ± 18.1 mmHg (pre-TAVI) to 10.3 ± 3.1 mmHg (1-year post-TAVI) (P < 0.001); aortic valve area increased from 0.6 ± 0.2 cm(2) (pre-TAVI) to 1.8 ± 0.4 cm(2) (1-year post-TAVI); these results remained stable over the 3 years of follow-up. Paravalvular leak was observed in the majority of patients. There were no cases of progression to moderate or severe regurgitation. No cases of structural valve deterioration were observed.ConclusionThis multicentre study demonstrates that TAVI with the 18-Fr CoreValve ReValving System is associated with sustained clinical and functional cardiovascular benefits in high-risk patients with symptomatic aortic stenosis up to 3-year follow-up. Non-cardiac causes accounted for the majority of deaths at follow-up.
2012
Ussia, Gp; Barbanti, M; Petronio, Anna; Tarantini, G; Ettori, F; Colombo, A; Violini, R; Ramondo, A; Santoro, G; Klugmann, S; Bedogni, F; Maisano, F; ...espandi
File in questo prodotto:
File Dimensione Formato  
61/97945432009630111860891548125503155398

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 216.31 kB
Formato Unknown
216.31 kB Unknown   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/157221
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 258
  • ???jsp.display-item.citation.isi??? 228
social impact