The use of a two mirrors Fabry-Perot suspended cavity as a high sensitivity displacement detector is considered. It can be used to test the remnant noises in VIRGO Super Attenuators. The displacement sensitivity of the apparatus should be increased up to the mirrors thermal noise limit.
Displacement measurement in VIRGO super attenuators with a suspended Fabry-Perot interferometer
FERRANTE, ISIDORO;FIDECARO, FRANCESCO;POGGIANI, ROSA;
1997-01-01
Abstract
The use of a two mirrors Fabry-Perot suspended cavity as a high sensitivity displacement detector is considered. It can be used to test the remnant noises in VIRGO Super Attenuators. The displacement sensitivity of the apparatus should be increased up to the mirrors thermal noise limit.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.