Purpose: To retrospectively evaluate the results of renal artery stenting in patients with renovascular disease and a solitary functioning kidney. Methods: Palmaz stents were placed in 16 patients with a solitary functioning kidney, renal artery stenosis, hypertension and renal failure. Stenoses were evaluated with color Doppler ultrasound, M,R angiography and digital subtraction angiography (DSA). Indications for stenting were: recoil after percutaneous transluminal renal angioplasty (PTRA) (63%), arterial dissection after PTRA (13%) and primary stenting (25%). Immediate results were evaluated by DSA. On follow-up (6-36 months), patients underwent periodical evaluation of clinical conditions (blood pressure and serum creatinine level) and stent patency, by means of color Doppler ultrasound. Results: Stent placement was successful in all patients (100%). Cumulative primary patency rate was: 100% at 1 day, 93.75% at 6 months, 81.25% at 12 months and 75% at 24 months. A significant reduction in diastolic blood pressure occurred (mean ± SD 104 ± 6 vs 92 ± 3; p < 0.05); renal function improved or stabilized in over 80% of patients. However, there was no significant difference in the creatinine values before and after treatment (mean ± SD 200 ± 142 μmol/1 vs 197 ± 182 μmol/1; p > 0.05). Conclusion: Renal artery stenting, both after PTRA and as primary stenting, represents a sate procedure, able to preserve renal function in patients with a solitary functioning kidney.
RENAL ARTERY STENTING IN PATIENTS WITH A SOLITARY FUNCTIONING KIDNEY
BARTOLOZZI, CARLO;NERI, EMANUELE;CARAMELLA, DAVIDE;PINTO, STEFANIA;
2001-01-01
Abstract
Purpose: To retrospectively evaluate the results of renal artery stenting in patients with renovascular disease and a solitary functioning kidney. Methods: Palmaz stents were placed in 16 patients with a solitary functioning kidney, renal artery stenosis, hypertension and renal failure. Stenoses were evaluated with color Doppler ultrasound, M,R angiography and digital subtraction angiography (DSA). Indications for stenting were: recoil after percutaneous transluminal renal angioplasty (PTRA) (63%), arterial dissection after PTRA (13%) and primary stenting (25%). Immediate results were evaluated by DSA. On follow-up (6-36 months), patients underwent periodical evaluation of clinical conditions (blood pressure and serum creatinine level) and stent patency, by means of color Doppler ultrasound. Results: Stent placement was successful in all patients (100%). Cumulative primary patency rate was: 100% at 1 day, 93.75% at 6 months, 81.25% at 12 months and 75% at 24 months. A significant reduction in diastolic blood pressure occurred (mean ± SD 104 ± 6 vs 92 ± 3; p < 0.05); renal function improved or stabilized in over 80% of patients. However, there was no significant difference in the creatinine values before and after treatment (mean ± SD 200 ± 142 μmol/1 vs 197 ± 182 μmol/1; p > 0.05). Conclusion: Renal artery stenting, both after PTRA and as primary stenting, represents a sate procedure, able to preserve renal function in patients with a solitary functioning kidney.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.