The MEG experiment at PSI searches for the decay mu -> e gamma at a level of approximate to 10(-13) on the branching ratio BR(mu -> e gamma/mu -> tot), well beyond the present experimental limit (BR <= 1.2 x 10(-11)) and is sensitive to the predictions of SUSY-GUT theories. To reach this goal the experiment uses one of the most intense continuous surface muon beams available (approximate to 10(8) mu/s) and relies on advanced technology (LXe calorimetry, a gradient-field superconducting spectrometer as well as flexible and powerful trigger and acquisition systems). In order to maintain the highest possible energy, time and spatial resolutions for such detector, frequent calibration and monitoring, using a Cockcroft-Walton proton accelerator, are required. The proton beam is brought to the centre of MEG by a special bellows insertion system and travels in a direction opposite to the one of the normal mu-beam. Protons interact with a lithium tetraborate (Li(2)B(4)O(7)) nuclear target and produce one gamma (17.6 MeV) from the reaction (7)(3)Li(p,gamma)(4)(8)Be or two coincident gamma s (11.67 and 4.4 MeV) from the reaction (11)(5)B(P,gamma(1))(6)(12)C*. The 17.6 MeV gamma is used for calibrating and monitoring the LXe calorimeter (sigma(E gamma)/E(gamma) = 3.85 +/- 0.15% at 17.6 MeV) while the coincident 11.67 and 4.4 MeV gamma s are used to measure the relative timing of the calorimeter and the spectrometer timing counters (sigma(Delta t) = 0.450 +/- 0.015 ns).

Calibration and monitoring of the MEG experiment by a proton beam from a Cockcroft-Walton accelerator

CEI, FABRIZIO;NICOLO', DONATO;Papa A;Signorelli G;TENCHINI, FRANCESCO;
2011-01-01

Abstract

The MEG experiment at PSI searches for the decay mu -> e gamma at a level of approximate to 10(-13) on the branching ratio BR(mu -> e gamma/mu -> tot), well beyond the present experimental limit (BR <= 1.2 x 10(-11)) and is sensitive to the predictions of SUSY-GUT theories. To reach this goal the experiment uses one of the most intense continuous surface muon beams available (approximate to 10(8) mu/s) and relies on advanced technology (LXe calorimetry, a gradient-field superconducting spectrometer as well as flexible and powerful trigger and acquisition systems). In order to maintain the highest possible energy, time and spatial resolutions for such detector, frequent calibration and monitoring, using a Cockcroft-Walton proton accelerator, are required. The proton beam is brought to the centre of MEG by a special bellows insertion system and travels in a direction opposite to the one of the normal mu-beam. Protons interact with a lithium tetraborate (Li(2)B(4)O(7)) nuclear target and produce one gamma (17.6 MeV) from the reaction (7)(3)Li(p,gamma)(4)(8)Be or two coincident gamma s (11.67 and 4.4 MeV) from the reaction (11)(5)B(P,gamma(1))(6)(12)C*. The 17.6 MeV gamma is used for calibrating and monitoring the LXe calorimeter (sigma(E gamma)/E(gamma) = 3.85 +/- 0.15% at 17.6 MeV) while the coincident 11.67 and 4.4 MeV gamma s are used to measure the relative timing of the calorimeter and the spectrometer timing counters (sigma(Delta t) = 0.450 +/- 0.015 ns).
2011
Adam, J; Bai, X; Baldini, A; Baracchini, E; Bemporad, C; Boca, G; Cattaneo, Pw; Cavoto, G; Cei, Fabrizio; Cerri, C; Corbo, M; Curalli, N; de Bari, A; ...espandi
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0168900211006875-main_MEGCW.pdf

non disponibili

Tipologia: Versione finale editoriale
Licenza: Importato da Ugov Ricerca - Accesso privato/ristretto
Dimensione 2.82 MB
Formato Adobe PDF
2.82 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/188428
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 29
social impact