We report the results of test beams performed at CERN using irradiated microstrip silicon detectors. The detectors were single- and double-sided devices, produced by different manufacturers and irradiated with neutrons at various fluences up to 3.6 × 10 13 n/cm 2. Signal-to-noise ratio, resolution and efficiency were studied for different values of the incidence angle, of the detector temperature and of the read-out pitch, as a function of the detector bias voltage. The goal of these tests was to optimize the design of the final prototypes for the CMS Silicon Strip Tracker.
Autori interni: | |
Autori: | Angarano M; Creanza D; De Palma M; Fiore L; Maggi G; My S; Pompili A; Raso G; Selvaggi G; Silvestris L; Tempesta P; Dinu N; Mihul A; Postolache V; Boemi D; Catacchini E; Civinini C; D'Alessandro R; Focardi E; Meschini M; Parrini G; Azzi P; Bacchetta N; Bisello D; Busetto G; Castro A; Loreti M; Martignon G; Pantano D; Stavitski I; Babucci E; Bartalini P; Bilei GM; Bizzaglia S; Checcucci B; Lariccia P; Mantovani G; Santocchia A; Servoli L; Bozzi C; Dell'Orso M; Messineo A; Tonelli G; Verdini PG |
Titolo: | Erratum to : Test beam results on irradiated silicon detectors for the CMS silicon strip tracker [Nucl. Instr. and Meth. A 434(1999) 313–336] |
Anno del prodotto: | 2000 |
Digital Object Identifier (DOI): | 10.1016/S0168-9002(99)01280-2 |
Appare nelle tipologie: | 1.1 Articolo in rivista |
File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.