The traditional methods for the assessment of insulin sensitivity yield only a single index, not the whole dose-response curve information. This curve is typically characterized by a maximally insulin-stimulated glucose clearance (Cl(max)) and an insulin concentration at half-maximal response (EC50). We developed an approach for estimating the whole dose-response curve with a single in vivo test, based on the use of tracer glucose and exogenous insulin administration (two steps of 20 and 200 mU·min-1·m-2, 100 min each). The effect of insulin on plasma glucose clearance was calculated from non-steady-state data by use of a circulatory model of glucose kinetics and a model of insulin action in which glucose clearance is represented as a Michaelis-Menten function of insulin concentration with a delay (t(1/2)). In seven nondiabetic subjects, the model predicted adequately the tracer concentration: the model residuals were unbiased, and their coefficient of variation was similar to the expected measurement error (~3%), indicating that the model did not introduce significant systematic errors. Lean (n = 4) and obese (n = 3) subjects had similar half-times for insulin action (t(1/2) = 25 ± 9 vs. 25 ± 8 min) and maximal responses (Cl(max) = 705 ± 46 vs. 668 ± 259 ml·min-1·m-2, respectively), whereas EC50 was 240 ± 84 μU/ml in the lean vs. 364 ± 229 μU/ml in the obese (P < 0.04). EC50 and the insulin sensitivity index (ISI, initial slope of the dose-response curve), but not Cl(max), were related to body adiposity and fat distribution with r of 0.6-0.8 (P < 0.05). Thus, despite the small number of study subjects, we were able to reproduce information consistent with the literature. In addition, among the lean individuals, t(1/2) was positively related to the ISI (r = 0.72, P < 0.02). We conclude that the test here presented, based on a more elaborate representation of glucose kinetics and insulin action, allows a reliable quantitation of the insulin dose-response curve for whole body glucose utilization in a single session of relatively short duration.

Determinants of postabsorptive endogenous glucose output in non-diabetic subjects

NATALI, ANDREA;CAMASTRA, STEFANIA;FERRANNINI, ELEUTERIO
2000-01-01

Abstract

The traditional methods for the assessment of insulin sensitivity yield only a single index, not the whole dose-response curve information. This curve is typically characterized by a maximally insulin-stimulated glucose clearance (Cl(max)) and an insulin concentration at half-maximal response (EC50). We developed an approach for estimating the whole dose-response curve with a single in vivo test, based on the use of tracer glucose and exogenous insulin administration (two steps of 20 and 200 mU·min-1·m-2, 100 min each). The effect of insulin on plasma glucose clearance was calculated from non-steady-state data by use of a circulatory model of glucose kinetics and a model of insulin action in which glucose clearance is represented as a Michaelis-Menten function of insulin concentration with a delay (t(1/2)). In seven nondiabetic subjects, the model predicted adequately the tracer concentration: the model residuals were unbiased, and their coefficient of variation was similar to the expected measurement error (~3%), indicating that the model did not introduce significant systematic errors. Lean (n = 4) and obese (n = 3) subjects had similar half-times for insulin action (t(1/2) = 25 ± 9 vs. 25 ± 8 min) and maximal responses (Cl(max) = 705 ± 46 vs. 668 ± 259 ml·min-1·m-2, respectively), whereas EC50 was 240 ± 84 μU/ml in the lean vs. 364 ± 229 μU/ml in the obese (P < 0.04). EC50 and the insulin sensitivity index (ISI, initial slope of the dose-response curve), but not Cl(max), were related to body adiposity and fat distribution with r of 0.6-0.8 (P < 0.05). Thus, despite the small number of study subjects, we were able to reproduce information consistent with the literature. In addition, among the lean individuals, t(1/2) was positively related to the ISI (r = 0.72, P < 0.02). We conclude that the test here presented, based on a more elaborate representation of glucose kinetics and insulin action, allows a reliable quantitation of the insulin dose-response curve for whole body glucose utilization in a single session of relatively short duration.
2000
Natali, Andrea; Toschi, E; Camastra, Stefania; Gastaldelli, A; Groop, L; Ferrannini, Eleuterio
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/190508
Citazioni
  • ???jsp.display-item.citation.pmc??? 20
  • Scopus 83
  • ???jsp.display-item.citation.isi??? 40
social impact