Purpose: To evaluate feasibility and image quality of time-resolved contrast-enhanced magnetic resonance angiography (CEMRA) of the left atrium-pulmonary veins (LA-PV) complex with half dose of intravenous gadolinium-based contrast agent (GBCA) in patients candidate to percutaneous radiofrequency ablation of atrial fibrillation. Methods and materials: Fifty-seven patients underwent CEMRA of the LA-PV complex on a 1.5 T MRI scanner. On 24/57 patients, a conventional fast-spoiled gradient-echo (FSPGR) CEMRA acquisition was run using 0.2 mL/kg of 0.5 M GBCA at 2 mL/s flow rate (protocol A), while in 33/57 patients a time-resolved multiphase CEMRA sequence (Time-Resolved Imaging of Contrast KineticS, TRICKS) was performed after intravenous injection of 0.1 mL/kg of the same GBCA at 3 mL/s flow rate (protocol B). Contrast enhancement was measured in the LA (LAe) and in the PA (PAe), and the LAe/PAe ratio was calculated. Diagnostic quality of Maximum Intensity Projection (MIP), Volume Rendering (VR), and Virtual Endoscopy (VE) reconstructions was also assessed visually using a semiquantitative score. Results: LAe was comparable with both protocols, while PAe was lower with protocol B than with protocol A (p = 0.0217). Moreover, the LAe/PAe ratio was significantly higher with protocol B than with protocol A (p = 0.0044). Finally, image quality of MIP, VR, and VE reconstructions was significantly better with protocol B than with protocol A (p = 0.0005, p = 0.0001, and p = 0.005, respectively). Conclusions: CEMRA of the LA-PV complex is feasible with TRICKS and half-dose GBCA and yields better separation between the LA-PV complex and the PA, as well as better image quality of MIP, VR, and VE reconstructions than a conventional FSPGR sequence performed with full GBCA dose.

Time-resolved contrast-enhanced magnetic resonance angiography (CEMRA) of the left atrium-pulmonary veins complex with half dose of intravenous gadolinium-based contrast agent. Technical feasibility and comparison with a conventional CEMRA, full contrast dose protocol.

Faggioni L;NERI, EMANUELE;BARTOLOZZI, CARLO
2012-01-01

Abstract

Purpose: To evaluate feasibility and image quality of time-resolved contrast-enhanced magnetic resonance angiography (CEMRA) of the left atrium-pulmonary veins (LA-PV) complex with half dose of intravenous gadolinium-based contrast agent (GBCA) in patients candidate to percutaneous radiofrequency ablation of atrial fibrillation. Methods and materials: Fifty-seven patients underwent CEMRA of the LA-PV complex on a 1.5 T MRI scanner. On 24/57 patients, a conventional fast-spoiled gradient-echo (FSPGR) CEMRA acquisition was run using 0.2 mL/kg of 0.5 M GBCA at 2 mL/s flow rate (protocol A), while in 33/57 patients a time-resolved multiphase CEMRA sequence (Time-Resolved Imaging of Contrast KineticS, TRICKS) was performed after intravenous injection of 0.1 mL/kg of the same GBCA at 3 mL/s flow rate (protocol B). Contrast enhancement was measured in the LA (LAe) and in the PA (PAe), and the LAe/PAe ratio was calculated. Diagnostic quality of Maximum Intensity Projection (MIP), Volume Rendering (VR), and Virtual Endoscopy (VE) reconstructions was also assessed visually using a semiquantitative score. Results: LAe was comparable with both protocols, while PAe was lower with protocol B than with protocol A (p = 0.0217). Moreover, the LAe/PAe ratio was significantly higher with protocol B than with protocol A (p = 0.0044). Finally, image quality of MIP, VR, and VE reconstructions was significantly better with protocol B than with protocol A (p = 0.0005, p = 0.0001, and p = 0.005, respectively). Conclusions: CEMRA of the LA-PV complex is feasible with TRICKS and half-dose GBCA and yields better separation between the LA-PV complex and the PA, as well as better image quality of MIP, VR, and VE reconstructions than a conventional FSPGR sequence performed with full GBCA dose.
2012
Faggioni, L; Zampa, V; Ortori, S; Picano, E; De Lucia, R; Soldati, E; Bongiorni, Mg; Neri, Emanuele; Bartolozzi, Carlo
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/191206
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 6
social impact