Background: The aim of the study was to assess the value of Pulsed-wave Doppler tissue imaging (DTI) in assessing diastolic and systolic function in patients with severe aortic value stenosis. Methods: Thirty-five patients with aortic stenosis (AS) (valve orifice less than or equal to 1 cm(2), mean age 71.8 +/- 6.2) and 35 comparable healthy subjects were studied. All subjects performed conventional 2-dimensional Doppler echocardiography and DTI at mitral annulus level. Patients with AS were divided into 2 groups: 16 patients who presented initial signs of HF and a depressed left ventricular systolic funciton (AS 1) (EF: 35%-50%) and 19 patients were asymptomatic and had normal left ventricular systolic function (EF > 50%) (ASH). The 16 symptomatic AS patients underwent surgical aortic valve replacement and were examined after 1 year. Results: DTI was able to detect abnormalities of systolic and diastolic function in AS: the significantly lower peak S velocity in AS I than in AS II and in controls, both at septum and lateral wall level; the significantly lower peak E velocity in AS I than in AS H and in controls both at septum and lateral wall level; the significantly higher peak A velocity in AS I than in AS II and in controls both at septum and lateral wall level; the significant lower E/A ratio in AS I than in AS U and in controls both at septum and lateral wall level. Conclusion: We found a significant inverse correlation between DTI lateral S velocity, DTI peak E velocity, lateral DTI E/A ratio, and AS peak and mean gradient. According to the results of this study we can affirm that DTI parameters surely had an important physiopathological impact in the knowledge of myocardial function in patients with severe aortic stenosis.

Myocardial function in severe aortic stenosis bifore and after aortic valve replacement: a Doppler tissue imaging study

DI BELLO, VITANTONIO;DI CORI A;MARIANI, MARIO
2005-01-01

Abstract

Background: The aim of the study was to assess the value of Pulsed-wave Doppler tissue imaging (DTI) in assessing diastolic and systolic function in patients with severe aortic value stenosis. Methods: Thirty-five patients with aortic stenosis (AS) (valve orifice less than or equal to 1 cm(2), mean age 71.8 +/- 6.2) and 35 comparable healthy subjects were studied. All subjects performed conventional 2-dimensional Doppler echocardiography and DTI at mitral annulus level. Patients with AS were divided into 2 groups: 16 patients who presented initial signs of HF and a depressed left ventricular systolic funciton (AS 1) (EF: 35%-50%) and 19 patients were asymptomatic and had normal left ventricular systolic function (EF > 50%) (ASH). The 16 symptomatic AS patients underwent surgical aortic valve replacement and were examined after 1 year. Results: DTI was able to detect abnormalities of systolic and diastolic function in AS: the significantly lower peak S velocity in AS I than in AS II and in controls, both at septum and lateral wall level; the significantly lower peak E velocity in AS I than in AS H and in controls both at septum and lateral wall level; the significantly higher peak A velocity in AS I than in AS II and in controls both at septum and lateral wall level; the significant lower E/A ratio in AS I than in AS U and in controls both at septum and lateral wall level. Conclusion: We found a significant inverse correlation between DTI lateral S velocity, DTI peak E velocity, lateral DTI E/A ratio, and AS peak and mean gradient. According to the results of this study we can affirm that DTI parameters surely had an important physiopathological impact in the knowledge of myocardial function in patients with severe aortic stenosis.
2005
Giorgi, D; DI BELLO, Vitantonio; Talini, E; Palagi, C; DELLE DONNE, Mg; Nardi, C; Verunelli, F; Mariani, Ma; DI CORI, A; Caravelli, P; Mariani, Mario
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/202186
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 34
social impact