PURPOSE: : This research sought first to evaluate the differences in the finite element method (FEM) analysis of 4 different implant surfaces, including internal and external connections of the same manufacturer with additional modifications. METHODS: : In this study, 4 dental implants from the same manufacturer were compared. A connection system was modified with a collar to improve its stability. A nonlinear dynamic analysis by FEM was used to calculate the transient response of the dental implant systems. RESULTS: : The results of FEM analysis indicated that the implant-modified configuration is more efficient in loading support when compared with the others. CONCLUSION: : In the present research, 4 different types of connections were evaluated: a modified internal hex connection with a collar (to increase stability), an internal hex connection, a standard connection without hex, and an external connection. These data demonstrated that the internal hex connection with the modification of the manufacturer's original is much more resistant to loosening and/or distortion than the traditional hex.

An evaluation of new designs in implant-abutment connections: a finite element method assessment.

COVANI, UGO;BARONE, ANTONIO
2013-01-01

Abstract

PURPOSE: : This research sought first to evaluate the differences in the finite element method (FEM) analysis of 4 different implant surfaces, including internal and external connections of the same manufacturer with additional modifications. METHODS: : In this study, 4 dental implants from the same manufacturer were compared. A connection system was modified with a collar to improve its stability. A nonlinear dynamic analysis by FEM was used to calculate the transient response of the dental implant systems. RESULTS: : The results of FEM analysis indicated that the implant-modified configuration is more efficient in loading support when compared with the others. CONCLUSION: : In the present research, 4 different types of connections were evaluated: a modified internal hex connection with a collar (to increase stability), an internal hex connection, a standard connection without hex, and an external connection. These data demonstrated that the internal hex connection with the modification of the manufacturer's original is much more resistant to loosening and/or distortion than the traditional hex.
2013
Covani, Ugo; Ricci, M; Tonelli, P; Barone, Antonio
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/208464
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 14
social impact