Wire delays and leakage energy consumption are both growing problems in the design of large on chip caches built in deep submicron technologies. D-NUCA caches (Dynamic-Nonuniform Cache Architecture) exploit an aggressive subbanking of the cache and a migration mechanism to speed up frequently accessed data access latency, to limit wire delays effects on performances. Way Adaptable D-NUCA is a leakage power reduction technique specifically suited for D-NUCA caches. It dynamically varies the portion of the powered-on cache area based on the running workload caching needs, but it relies on application dependent parameters that must be evaluated off-line. This limits the effectiveness of Way Adaptable D-NUCA in the general purpose, multiprogrammed environment. In this paper, we propose a new power reduction technique for D-NUCA caches, which still adapts the powered-on cache area to the needs of the running workload, but it does not rely on application-dependent parameters. Results show that our proposal saves around 49 % of total cache energy consumption in a single core environment and 44 % in CMP environment. By adding a timer, it performs similarly to previously proposed techniques to reduce leakage power consumptions, and outperforms them when they are applied in a workload independent manner.

A Workload Independent Energy Reduction Strategy for D-NUCA Caches

FOGLIA, PIERFRANCESCO
2014-01-01

Abstract

Wire delays and leakage energy consumption are both growing problems in the design of large on chip caches built in deep submicron technologies. D-NUCA caches (Dynamic-Nonuniform Cache Architecture) exploit an aggressive subbanking of the cache and a migration mechanism to speed up frequently accessed data access latency, to limit wire delays effects on performances. Way Adaptable D-NUCA is a leakage power reduction technique specifically suited for D-NUCA caches. It dynamically varies the portion of the powered-on cache area based on the running workload caching needs, but it relies on application dependent parameters that must be evaluated off-line. This limits the effectiveness of Way Adaptable D-NUCA in the general purpose, multiprogrammed environment. In this paper, we propose a new power reduction technique for D-NUCA caches, which still adapts the powered-on cache area to the needs of the running workload, but it does not rely on application-dependent parameters. Results show that our proposal saves around 49 % of total cache energy consumption in a single core environment and 44 % in CMP environment. By adding a timer, it performs similarly to previously proposed techniques to reduce leakage power consumptions, and outperforms them when they are applied in a workload independent manner.
2014
M., Comparetti; Foglia, Pierfrancesco
File in questo prodotto:
File Dimensione Formato  
JS2013.pdf

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.86 MB
Formato Adobe PDF
1.86 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/272136
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 8
social impact