Ultrafiltration (UF) has been presented as an alternative to chemical disinfection to obtain safe drinking water, for its ability to remove microbiological contamination. Hollow-fiber UF membranes are designed as an effective barrier to microorganisms, for their high manufacturing integrity and for the "potting" method adopted to seal fibers to the feeding/extraction manifold. While the main advantage over chemical disinfection is the drastic reduction of disinfection-by-product (DBP) formation, some chemicals are still required to control fouling and related sanitary risks. This study aims at an up-to-date assessment of UF use for surface water disinfection by compact, minimally-attended, automated plants. A 3.5 m3/h automated UF pilot-plant was run for eight months for drinking quality purification of surface water from Pescia stream. Standard drinking water parameters, as well as specific microbiological parameters (Legionella, Mycobacterium, Adenovirus, Coliphage) and DBP formation were monitored. Final results highlighted that the plant could reach a good removal of bacteria and a significant reduction of viruses. However, the adopted operation/maintenance policies had a strong impact on energy and water consumption, efficacy of bacterium/virus barrier and DBP formation. Hence, an accurate and competent operation, as well as the assistance of chemical disinfection, are still required for safe drinking water production.

Feasibility assessment of surface water disinfection by ultrafiltration

IANNELLI, RENATO;CASINI, BEATRICE;PRIVITERA, GAETANO PIERPAOLO;VERANI, MARCO;CARDUCCI, ANNALAURA
2014-01-01

Abstract

Ultrafiltration (UF) has been presented as an alternative to chemical disinfection to obtain safe drinking water, for its ability to remove microbiological contamination. Hollow-fiber UF membranes are designed as an effective barrier to microorganisms, for their high manufacturing integrity and for the "potting" method adopted to seal fibers to the feeding/extraction manifold. While the main advantage over chemical disinfection is the drastic reduction of disinfection-by-product (DBP) formation, some chemicals are still required to control fouling and related sanitary risks. This study aims at an up-to-date assessment of UF use for surface water disinfection by compact, minimally-attended, automated plants. A 3.5 m3/h automated UF pilot-plant was run for eight months for drinking quality purification of surface water from Pescia stream. Standard drinking water parameters, as well as specific microbiological parameters (Legionella, Mycobacterium, Adenovirus, Coliphage) and DBP formation were monitored. Final results highlighted that the plant could reach a good removal of bacteria and a significant reduction of viruses. However, the adopted operation/maintenance policies had a strong impact on energy and water consumption, efficacy of bacterium/virus barrier and DBP formation. Hence, an accurate and competent operation, as well as the assistance of chemical disinfection, are still required for safe drinking water production.
2014
Iannelli, Renato; S., Ripari; Casini, Beatrice; A., Buzzigoli; Privitera, GAETANO PIERPAOLO; Verani, Marco; Carducci, Annalaura
File in questo prodotto:
File Dimensione Formato  
2014 Iannelli etal WS-EM13159R1.pdf

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 190.21 kB
Formato Adobe PDF
190.21 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/339067
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
social impact