Background Myocardial iron overload assessment by multislice multiecho T2* technique is used in the clinical management of thalassemia major (TM) patients. Signal decay curves are extracted from the 16 left ventricular (LV) segments and the fitting of these curves to a mono-exponential model provides the corresponding T2* values. In patients with severe cardiac iron overload, where signal will decay quickly becoming comparable to image noise, manual truncation of signal decay curves excluding later echo times (TEs) is adopted. In this study an automatic truncation method avoiding the variability associated with the manual selection of the truncation point is introduced and validated. Go to: Methods Twenty patients (13 males, age 33±7 years) enrolled in the MIOT Network and diagnosed for severe iron overload (T2*<10 ms) were considered. Using a previously validated software the segmental T2* values were evaluated by the standard methodology (i.e. manual truncation). Images were independently analysed by the developed automated approach. The percentage fitting error (e) was computed as the root mean square error (MRSE) between the signal decay curve and the mono-exponential model normalized to the mean value of the signal. If e was > 5%, the algorithm cut-off the last TE and performed again the fitting. The procedure was iterated until the error become <5% or the number of TEs become equal to three. To assess the inter-operator variability, the dataset was processed by a second operator. Go to: Results The Coefficient of Variability (CoV) for inter-observer variability was 6.82±4.01%. The CoV between automated and manual analysis was 6.15±3.92 %, not significantly different from inter-observer variability (P=0.332). No significant difference was detected between mid-septum and global T2* values evaluated with manual and automated procedure (P=0.26 and P=0.91, respectively). The mean fitting error was not significantly different in manual and automated analysis (4.10±2.11 vs. 4.52±2.12, P=0.53). In segmental analysis, no significant differences were found between manual and automatic procedure (P>0.01 for all segments). Figure ​Figure11 shows the Bland-Altmann plots for global heart and mid-ventricular septum T2* measurements (a) and for segmental T2* values (b). Figure 1 Figure 1 Go to: Conclusions Truncation of signal decay curve needed to compensate for low signal in later echoes in patients with severe iron overload can be effectively automatized avoiding operator induced variability.

An automatic method for myocardial T2(star) curve fitting in thalassemia patients with severe iron overload

LANDINI, LUIGI;
2013-01-01

Abstract

Background Myocardial iron overload assessment by multislice multiecho T2* technique is used in the clinical management of thalassemia major (TM) patients. Signal decay curves are extracted from the 16 left ventricular (LV) segments and the fitting of these curves to a mono-exponential model provides the corresponding T2* values. In patients with severe cardiac iron overload, where signal will decay quickly becoming comparable to image noise, manual truncation of signal decay curves excluding later echo times (TEs) is adopted. In this study an automatic truncation method avoiding the variability associated with the manual selection of the truncation point is introduced and validated. Go to: Methods Twenty patients (13 males, age 33±7 years) enrolled in the MIOT Network and diagnosed for severe iron overload (T2*<10 ms) were considered. Using a previously validated software the segmental T2* values were evaluated by the standard methodology (i.e. manual truncation). Images were independently analysed by the developed automated approach. The percentage fitting error (e) was computed as the root mean square error (MRSE) between the signal decay curve and the mono-exponential model normalized to the mean value of the signal. If e was > 5%, the algorithm cut-off the last TE and performed again the fitting. The procedure was iterated until the error become <5% or the number of TEs become equal to three. To assess the inter-operator variability, the dataset was processed by a second operator. Go to: Results The Coefficient of Variability (CoV) for inter-observer variability was 6.82±4.01%. The CoV between automated and manual analysis was 6.15±3.92 %, not significantly different from inter-observer variability (P=0.332). No significant difference was detected between mid-septum and global T2* values evaluated with manual and automated procedure (P=0.26 and P=0.91, respectively). The mean fitting error was not significantly different in manual and automated analysis (4.10±2.11 vs. 4.52±2.12, P=0.53). In segmental analysis, no significant differences were found between manual and automatic procedure (P>0.01 for all segments). Figure ​Figure11 shows the Bland-Altmann plots for global heart and mid-ventricular septum T2* measurements (a) and for segmental T2* values (b). Figure 1 Figure 1 Go to: Conclusions Truncation of signal decay curve needed to compensate for low signal in later echoes in patients with severe iron overload can be effectively automatized avoiding operator induced variability.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/444471
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact