Both commercial 7-pixel and experimental 19-pixel HPD tubes have been tested for response uniformity. The integrated charge response indicates a uniformity close to the percent level both across the surface of each pixel and the pixel-to-pixel borders. Full response uniformity is obtained only well above the Si-diode full-depletion voltage. In order to better understand this fact, the charge collection process has been thoroughly studied as a function of bias and position, thereby offering an explanation to some of the nonuniformities. Occasionally small dimples and scars are seen to spoil the HPD uniformity. These dimples were found to be caused by high power, strongly focused light bursts produced during the setup time and were observed to fade and disappear in the time scale of days. Finally the seven pixel HPDs were used to localize an optical fiber emitting light flashes of variable amplitude; 150 mu m position resolution with 100 photoelectron light pulse amplitude were achieved.

Characterization of multi-pixel HPD tubes

POGGIANI, ROSA;
1997-01-01

Abstract

Both commercial 7-pixel and experimental 19-pixel HPD tubes have been tested for response uniformity. The integrated charge response indicates a uniformity close to the percent level both across the surface of each pixel and the pixel-to-pixel borders. Full response uniformity is obtained only well above the Si-diode full-depletion voltage. In order to better understand this fact, the charge collection process has been thoroughly studied as a function of bias and position, thereby offering an explanation to some of the nonuniformities. Occasionally small dimples and scars are seen to spoil the HPD uniformity. These dimples were found to be caused by high power, strongly focused light bursts produced during the setup time and were observed to fade and disappear in the time scale of days. Finally the seven pixel HPDs were used to localize an optical fiber emitting light flashes of variable amplitude; 150 mu m position resolution with 100 photoelectron light pulse amplitude were achieved.
1997
Waldron, L; Benetti, P; Desalvo, R; Grassi, D; Poggiani, Rosa; Rossella, M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/46662
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact