Two different approaches for the automatic compensation of pressure effects on thermal flow sensors are investigated. One approach operates in the analog domain and it is based on a closed-loop circuit that uses a pressure dependent signal to keep the sensor output constant. The digital approach operates in an open loop fashion and is capable of producing also a pressure reading. The effectiveness of the proposed methods has been verified by means of a smart flow sensor integrating on the same chip the sensing structures and a configurable electronic interface performing signal reading and non idealities compensation. The chip has been designed with a commercial CMOS process and fabricated by means of a post-processing technique. The experimental results performed in nitrogen confirm that both methods are capable of reducing the sensitivity of the flow sensor output signal to pressure variations

Automatic compensation of pressure effects on smart flow sensors in the analog and digital domain

PIOTTO, MASSIMO;LONGHITANO, AURELIO NUNZIO;DEL CESTA, FRANCESCO;BRUSCHI, PAOLO
2014-01-01

Abstract

Two different approaches for the automatic compensation of pressure effects on thermal flow sensors are investigated. One approach operates in the analog domain and it is based on a closed-loop circuit that uses a pressure dependent signal to keep the sensor output constant. The digital approach operates in an open loop fashion and is capable of producing also a pressure reading. The effectiveness of the proposed methods has been verified by means of a smart flow sensor integrating on the same chip the sensing structures and a configurable electronic interface performing signal reading and non idealities compensation. The chip has been designed with a commercial CMOS process and fabricated by means of a post-processing technique. The experimental results performed in nitrogen confirm that both methods are capable of reducing the sensitivity of the flow sensor output signal to pressure variations
2014
Piotto, Massimo; Longhitano, AURELIO NUNZIO; DEL CESTA, Francesco; Bruschi, Paolo
File in questo prodotto:
File Dimensione Formato  
59_Flow_e_pressure_2013.pdf

non disponibili

Tipologia: Versione finale editoriale
Licenza: Importato da Ugov Ricerca - Accesso privato/ristretto
Dimensione 1.67 MB
Formato Adobe PDF
1.67 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
post_print.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Creative commons
Dimensione 629.71 kB
Formato Adobe PDF
629.71 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/538952
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact