Microvalves are commonly used in microfluidic systems to control precisely the liquid flow. In this paper, the design and fabrication of a normally-closed (NC) all-polymer membrane-type microvalve is described. The microvalve with a diameter and thickness of 5mm and 3 mm, respectively, is fabricated completely in biocompatible polydimethylsiloxane (PDMS). The opening pressure, which depends on the adhesion between the membrane and the slab, is reduced to the noticeably low value of 3.4 kPa by the surface oxidation of the PDMS layers. This technique in combination with a selective bonding by Polyethylene terephthalate (PET) shadow masking allows for the fabrication of a high reverse pressure microvalve (no flow up to 0.6 MPa reverse pressure). Other major fabrication steps include PDMS doctor-blading and soft lithography in order to fabricate the thin and surface patterned membranes, respectively. The presented microvalve features a minimum flow rate of 1.0 ml min(-1).

PDMS Selective Bonding for the Fabrication of Biocompatible All Polymer NC Microvalves

SALVO, PIETRO;
2013-01-01

Abstract

Microvalves are commonly used in microfluidic systems to control precisely the liquid flow. In this paper, the design and fabrication of a normally-closed (NC) all-polymer membrane-type microvalve is described. The microvalve with a diameter and thickness of 5mm and 3 mm, respectively, is fabricated completely in biocompatible polydimethylsiloxane (PDMS). The opening pressure, which depends on the adhesion between the membrane and the slab, is reduced to the noticeably low value of 3.4 kPa by the surface oxidation of the PDMS layers. This technique in combination with a selective bonding by Polyethylene terephthalate (PET) shadow masking allows for the fabrication of a high reverse pressure microvalve (no flow up to 0.6 MPa reverse pressure). Other major fabrication steps include PDMS doctor-blading and soft lithography in order to fabricate the thin and surface patterned membranes, respectively. The presented microvalve features a minimum flow rate of 1.0 ml min(-1).
2013
Jahanshahi, A.; Salvo, Pietro; Vanfleteren, J.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/607270
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact