Introduction The purpose of the study was to verify the efficacy of using internal jugular vein (IJV) size and distensibility as a reliable index of fluid responsiveness in mechanically ventilated patients with sepsis. Methods Hemodynamic data of mechanically ventilated patients with sepsis were collected through a radial arterial indwelling catheter connected to continuous hemodynamic monitoring system (Most Care®, Vytech Health, Padova, Italy), including cardiac index (CI) (L/min/M2), heart rate (beats/min), mean arterial pressure (MAP) (mmHg), central venous pressure (CVP) (mmHg) and arterial pulse pressure variation (PPV), coupled with ultrasound evaluation of IJV distensibility (%), defined as a ratio of the difference between IJV maximal antero-posterior diameter during inspiration and minimum expiratory diameter to minimum expiratory diameter x100. Patients were retrospectively divided into two groups; fluid responders (R), if CI increase of more than or equal to 15% after a 7 ml/kg crystalloid infusion, and non-responders (NR) if CI increased more than 15%. We compared differences in measured variables between R and NR groups and calculated receiver-operator-characteristic (ROC) curves of optimal IJV distensibility and PPV sensitivity and specificity to predicting R. We also calculated a combined inferior vena cava distensibility-PPV ROC curve to predict R. Results We enrolled 50 patients, of these, 30 were R. Responders presented higher IJV distensibility and PPV before fluid challenge than NR (P <0.05). An IJV distensibility more than 18% prior to volume challenge had an 80% sensitivity and 85% specificity to predict R. Pairwise comparison between IJV distensibility and PPV ROC curves revealed similar ROC area under the curve results. Interestingly, combining IJV distensibility more than 9.7% and PPV more than 12% predicted fluid responsiveness with a sensitivity of 100% and specificity of 95%. Conclusion IJV distensibility is an accurate, easily acquired non-invasive parameter of fluid responsiveness in mechanically ventilated septic patients with performance similar to PPV. The combined use of IJV distensibility with left-sided indexes of fluid responsiveness improves their predictive value.

Jugular vein distensibility predicts fluid responsiveness in septic patients

FORFORI, FRANCESCO;
2014-01-01

Abstract

Introduction The purpose of the study was to verify the efficacy of using internal jugular vein (IJV) size and distensibility as a reliable index of fluid responsiveness in mechanically ventilated patients with sepsis. Methods Hemodynamic data of mechanically ventilated patients with sepsis were collected through a radial arterial indwelling catheter connected to continuous hemodynamic monitoring system (Most Care®, Vytech Health, Padova, Italy), including cardiac index (CI) (L/min/M2), heart rate (beats/min), mean arterial pressure (MAP) (mmHg), central venous pressure (CVP) (mmHg) and arterial pulse pressure variation (PPV), coupled with ultrasound evaluation of IJV distensibility (%), defined as a ratio of the difference between IJV maximal antero-posterior diameter during inspiration and minimum expiratory diameter to minimum expiratory diameter x100. Patients were retrospectively divided into two groups; fluid responders (R), if CI increase of more than or equal to 15% after a 7 ml/kg crystalloid infusion, and non-responders (NR) if CI increased more than 15%. We compared differences in measured variables between R and NR groups and calculated receiver-operator-characteristic (ROC) curves of optimal IJV distensibility and PPV sensitivity and specificity to predicting R. We also calculated a combined inferior vena cava distensibility-PPV ROC curve to predict R. Results We enrolled 50 patients, of these, 30 were R. Responders presented higher IJV distensibility and PPV before fluid challenge than NR (P <0.05). An IJV distensibility more than 18% prior to volume challenge had an 80% sensitivity and 85% specificity to predict R. Pairwise comparison between IJV distensibility and PPV ROC curves revealed similar ROC area under the curve results. Interestingly, combining IJV distensibility more than 9.7% and PPV more than 12% predicted fluid responsiveness with a sensitivity of 100% and specificity of 95%. Conclusion IJV distensibility is an accurate, easily acquired non-invasive parameter of fluid responsiveness in mechanically ventilated septic patients with performance similar to PPV. The combined use of IJV distensibility with left-sided indexes of fluid responsiveness improves their predictive value.
2014
Guarracino, F; Ferro, B; Forfori, Francesco; Bertini, P; Magliacane, L; Pinsky, Mr
File in questo prodotto:
File Dimensione Formato  
Jugular vein distensibility predicts fluid responsiveness in septic patients.pdf

accesso aperto

Tipologia: Versione finale editoriale
Licenza: Creative commons
Dimensione 2.3 MB
Formato Adobe PDF
2.3 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/669664
Citazioni
  • ???jsp.display-item.citation.pmc??? 26
  • Scopus 65
  • ???jsp.display-item.citation.isi??? 56
social impact