For the Compact LInear Collider (CLIC) project at CERN, maintaining low emittance beams, as they are transported along the two independent 10-20 km long main linacs, is crucial. The beam trajectory therefore has to be very well aligned to the magnetic centre of the quadrupole magnets. A series of microwave cavity beam position monitors (BPM) is foreseen to detect the position of the beam along the main linacs to precisely monitor the beam trajectory in the circular beam pipe of only 8 mm diameter. The PACMAN project aims to demonstrate the pre-alignment of the magnetic field of a main CLIC quadrupole with the electro-magnetic centre of a 15 GHz RF-BPM to the required sub-micron accuracy. This paper focuses on stretched-wire measurements of a CLIC Test Facility (CTF) cavity BPM, to locate its electrical centre. Details of two measurement methods are discussed: RF signal excitation of the wire and analysis of RF signal transfer through the slot-coupled waveguides of the cavity, using the stretched wire as a passive target. This contribution will present the theory behind these measurements, their electromagnetic analysis and first, preliminary experimental results.

Stretched-Wire Techniques and Measurements for the Alignment of a 15GHz RF-BPM for CLIC

FANUCCI, LUCA;
2015-01-01

Abstract

For the Compact LInear Collider (CLIC) project at CERN, maintaining low emittance beams, as they are transported along the two independent 10-20 km long main linacs, is crucial. The beam trajectory therefore has to be very well aligned to the magnetic centre of the quadrupole magnets. A series of microwave cavity beam position monitors (BPM) is foreseen to detect the position of the beam along the main linacs to precisely monitor the beam trajectory in the circular beam pipe of only 8 mm diameter. The PACMAN project aims to demonstrate the pre-alignment of the magnetic field of a main CLIC quadrupole with the electro-magnetic centre of a 15 GHz RF-BPM to the required sub-micron accuracy. This paper focuses on stretched-wire measurements of a CLIC Test Facility (CTF) cavity BPM, to locate its electrical centre. Details of two measurement methods are discussed: RF signal excitation of the wire and analysis of RF signal transfer through the slot-coupled waveguides of the cavity, using the stretched wire as a passive target. This contribution will present the theory behind these measurements, their electromagnetic analysis and first, preliminary experimental results.
2015
978-3-95450-176-2
File in questo prodotto:
File Dimensione Formato  
tupb063.pdf

accesso aperto

Tipologia: Versione finale editoriale
Licenza: Creative commons
Dimensione 2.16 MB
Formato Adobe PDF
2.16 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/783039
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? ND
social impact