Rotating stall is a key problem in centrifugal compressors especially for high-pressure applications. Among the several solutions proposed to prevent this problem, low solidity vaned diffusers (LSDs) have been successfully applied. The aim of this research is to find an optimized LSD configuration in terms of stall inception and performance for the tested compressor. The influence of the vane leading and trailing edge radii, maintaining the same solidity and null deflection were investigated. The geometrical parameters of tested configurations were methodically chosen in order to achieve a design of experiment (DOE) analysis. In view of the above, a series of tests on five low solidity vaned diffuser configurations were carried out. Tests allowed determination of 2 different LSDs that showed the best behavior in terms of working range and performance. These LSDs were then compared with the standard and the reduced-width vaneless diffuser to better understand the best solution to the stall problem.

Application of low solidity vaned diffusers to prevent rotating stall in centrifugal compressors: experimental investigation

FERRARI, LORENZO;
2003-01-01

Abstract

Rotating stall is a key problem in centrifugal compressors especially for high-pressure applications. Among the several solutions proposed to prevent this problem, low solidity vaned diffusers (LSDs) have been successfully applied. The aim of this research is to find an optimized LSD configuration in terms of stall inception and performance for the tested compressor. The influence of the vane leading and trailing edge radii, maintaining the same solidity and null deflection were investigated. The geometrical parameters of tested configurations were methodically chosen in order to achieve a design of experiment (DOE) analysis. In view of the above, a series of tests on five low solidity vaned diffuser configurations were carried out. Tests allowed determination of 2 different LSDs that showed the best behavior in terms of working range and performance. These LSDs were then compared with the standard and the reduced-width vaneless diffuser to better understand the best solution to the stall problem.
2003
0-7918-3671-1
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/824817
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact