High energy physics experiments at the high intensity frontier place ever greater demands on detectors, and in particular on tracking devices. In order to compare the performance of small size tracking prototypes, a high resolution cosmic ray tracker has been assembled to provide an external track reference. It consists of four spare ladders of the external layers of the Silicon Vertex Tracker of the BaBar experiment. The test facility, operating at INFN Sezione di Pisa, provides the detector under test with an external track with an intrinsic resolution of 15-30 μm. The MEG II tracker is conceived as a unique volume wire drift chamber filled with He-isobutane 85-15%. The ionization density in this gas mixture is about 13 clusters/cm and this results in a non-negligible bias of the impact parameters for tracks crossing the cell close to the anode wire. We present the telescope performance in terms of tracking efficiency and resolution and the results of the characterization of a MEG II drift chamber prototype.

MEG II drift chamber characterization with the silicon based cosmic ray tracker at INFN Pisa

CEI, FABRIZIO;NICOLO', DONATO;
2016-01-01

Abstract

High energy physics experiments at the high intensity frontier place ever greater demands on detectors, and in particular on tracking devices. In order to compare the performance of small size tracking prototypes, a high resolution cosmic ray tracker has been assembled to provide an external track reference. It consists of four spare ladders of the external layers of the Silicon Vertex Tracker of the BaBar experiment. The test facility, operating at INFN Sezione di Pisa, provides the detector under test with an external track with an intrinsic resolution of 15-30 μm. The MEG II tracker is conceived as a unique volume wire drift chamber filled with He-isobutane 85-15%. The ionization density in this gas mixture is about 13 clusters/cm and this results in a non-negligible bias of the impact parameters for tracks crossing the cell close to the anode wire. We present the telescope performance in terms of tracking efficiency and resolution and the results of the characterization of a MEG II drift chamber prototype.
2016
Venturini, Marco; Baldini, A. M.; Baracchini, E.; Cei, Fabrizio; D'Onofrio, A.; Dussoni, Simeone; Galli, Luca; Grassi, M.; Nicolo', Donato; Signorelli, Giovanni
File in questo prodotto:
File Dimensione Formato  
MEG II drift chamber

solo utenti autorizzati

Descrizione: Testo completo
Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 494.55 kB
Formato Adobe PDF
494.55 kB Adobe PDF   Visualizza/Apri   Richiedi una copia