Current standards introduce different test methods to be used for the determination of the dynamic properties of polymers. Some of these have been applied in the last years for the evaluation of the thermoviscoelastic properties of interlayer in laminated glass. Even the latest draft standards, which provide test methods for the determination of mechanical properties of laminated glass interlayers, hesitate in providing a definite test procedure and thus allow the use of three different test methods depending on the kind of interlayer. Here, a short review of the test methods collected from the literature is proposed and some considerations are made regarding their strengths and weaknesses. The scope of studies surveyed does not claim to be exhaustive, but simply to be representative of the variety of procedures employed in research. The necessity is stressed to converge to as limited a number of test methods as possible that are also adequately simple and can therefore be applied in most research laboratories

Test Methods for the Determination of Interlayer Properties in Laminated Glass

ZULLI, FABIO;ANDREOZZI, LAURA;
2017-01-01

Abstract

Current standards introduce different test methods to be used for the determination of the dynamic properties of polymers. Some of these have been applied in the last years for the evaluation of the thermoviscoelastic properties of interlayer in laminated glass. Even the latest draft standards, which provide test methods for the determination of mechanical properties of laminated glass interlayers, hesitate in providing a definite test procedure and thus allow the use of three different test methods depending on the kind of interlayer. Here, a short review of the test methods collected from the literature is proposed and some considerations are made regarding their strengths and weaknesses. The scope of studies surveyed does not claim to be exhaustive, but simply to be representative of the variety of procedures employed in research. The necessity is stressed to converge to as limited a number of test methods as possible that are also adequately simple and can therefore be applied in most research laboratories
2017
Ranocchiai, Giovanna; Zulli, Fabio; Andreozzi, Laura; Fagone, Mario
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/844328
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 10
social impact