The analytical performances of needle trap micro-extraction (NTME) coupled with gas chromatography tandem mass spectrometry were evaluated by analyzing a mixture of twenty-two representative breath VOCs belonging to different chemical classes (i.e. hydrocarbons, ketones, aldehydes, aromatics and sulfurs). NTME is an emerging technique that guarantees detection limits in pptv range by pre-concentrating low volumes of sample, and it is particularly suitable for breath analysis. For most VOCs, detection limits between 20 and 500 pptv were obtained by pre-concentrating 25 mL of a humidified standard gas mixture at a flow rate of 15 mL/min. For all compounds, inter- and intra-day precisions were always below 15%, confirming the reliability of the method. The procedure was successfully applied to the analysis of exhaled breath samples collected from forty heart failure patients during their stay in the University Hospital of Pisa. The majority of patients (about 80%) showed a significant decrease of breath acetone levels (a factor of 3 or higher) at discharge compared to admission (acute phase) in correspondence to the improved clinical conditions during hospitalization, thus making this compound eligible as a biomarker of heart failure exacerbation.

Determination of volatile organic compounds in exhaled breath of heart failure patients by needle trap micro-extraction coupled with gas chromatography-tandem mass spectrometry

BIAGINI, DENISE
Primo
;
LOMONACO, TOMMASO
;
GHIMENTI, SILVIA;BELLAGAMBI, FRANCESCA;ONOR, MASSIMO;SCALI, MARIA CHIARA;BARLETTA, VALENTINA;MARZILLI, MARIO;SALVO, PIETRO;TRIVELLA, MARIA GIOVANNA;FUOCO, ROGER;DI FRANCESCO, FABIO
2017-01-01

Abstract

The analytical performances of needle trap micro-extraction (NTME) coupled with gas chromatography tandem mass spectrometry were evaluated by analyzing a mixture of twenty-two representative breath VOCs belonging to different chemical classes (i.e. hydrocarbons, ketones, aldehydes, aromatics and sulfurs). NTME is an emerging technique that guarantees detection limits in pptv range by pre-concentrating low volumes of sample, and it is particularly suitable for breath analysis. For most VOCs, detection limits between 20 and 500 pptv were obtained by pre-concentrating 25 mL of a humidified standard gas mixture at a flow rate of 15 mL/min. For all compounds, inter- and intra-day precisions were always below 15%, confirming the reliability of the method. The procedure was successfully applied to the analysis of exhaled breath samples collected from forty heart failure patients during their stay in the University Hospital of Pisa. The majority of patients (about 80%) showed a significant decrease of breath acetone levels (a factor of 3 or higher) at discharge compared to admission (acute phase) in correspondence to the improved clinical conditions during hospitalization, thus making this compound eligible as a biomarker of heart failure exacerbation.
2017
Biagini, Denise; Lomonaco, Tommaso; Ghimenti, Silvia; Bellagambi, Francesca; Onor, Massimo; Scali, MARIA CHIARA; Barletta, Valentina; Marzilli, Mario;...espandi
File in questo prodotto:
File Dimensione Formato  
Determination of volatile organic compounds in exhaled breath.pdf

accesso aperto

Tipologia: Versione finale editoriale
Licenza: Creative commons
Dimensione 1.58 MB
Formato Adobe PDF
1.58 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/877261
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 59
  • ???jsp.display-item.citation.isi??? 53
social impact