An accurate estimation of rotating stall is one of the key points for high-pressure centrifugal compressors, as it is often connected with the onset of detrimental subsynchronous vibrations which can prevent the machine from operating beyond this limit. With particular reference to vaneless diffuser rotating stall, the most common practice in industrial machines is to make use of a limited number of dynamic pressure probes to reconstruct the stall characteristics after an ensemble averaging approach. In this study, a 1:1 model of an industrial compressor stage was tested in a dedicated test rig and equipped with 24 pressure probes properly distributed along the diffuser circumference with the scope of providing a real-time visualization of the spatial pressure distribution within the diffuser. The results allowed the assessment of some important characteristics of the stall cells that were historically supposed based on averaged data, e.g. the cells rigidity. Moreover, the present study confirmed the existence of a stall pattern with two almost axisymmetric lobes. Finally, the transient analysis of both the stall inception and the surge onset was carried out, highlighting the flow field evolution in the diffuser under these conditions.

Experimental analysis of the pressure field inside a vaneless diffuser from rotating stall inception to surge

Ferrari, Lorenzo
;
2015-01-01

Abstract

An accurate estimation of rotating stall is one of the key points for high-pressure centrifugal compressors, as it is often connected with the onset of detrimental subsynchronous vibrations which can prevent the machine from operating beyond this limit. With particular reference to vaneless diffuser rotating stall, the most common practice in industrial machines is to make use of a limited number of dynamic pressure probes to reconstruct the stall characteristics after an ensemble averaging approach. In this study, a 1:1 model of an industrial compressor stage was tested in a dedicated test rig and equipped with 24 pressure probes properly distributed along the diffuser circumference with the scope of providing a real-time visualization of the spatial pressure distribution within the diffuser. The results allowed the assessment of some important characteristics of the stall cells that were historically supposed based on averaged data, e.g. the cells rigidity. Moreover, the present study confirmed the existence of a stall pattern with two almost axisymmetric lobes. Finally, the transient analysis of both the stall inception and the surge onset was carried out, highlighting the flow field evolution in the diffuser under these conditions.
2015
9780791856659
File in questo prodotto:
File Dimensione Formato  
05_GT2015_42282.pdf

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 8.06 MB
Formato Adobe PDF
8.06 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.