In a linear Fresnel plant adopting slightly curved primary mirrors (cylindrical or parabolic), a significant gain in the collected radiation can be achieved using primary mirrors with different focal lengths, dependent on the position of the mirror with respect to the receiver. This work introduces a universal function that provides the optimal focal length of a mirror, given only the mirror’s position relative to the receiver and the latitude, for a NS-oriented collector with a flat horizontal effective target. In a solar plant with the focal lengths defined by this function, the efficiency gain with respect to a solar field adopting identical mirrors is estimated in the range 1.5–6%, with the gain increasing if mirror imperfections or tracking errors are present: this means that the regulation of the focal lengths is especially useful in containing the loss of efficiency due to defects. The given rule is tolerant to errors in the focal length regulation (up to 10%). The function can be used as a reference for future projects, or as a starting point for more refined optimizations.

Optimal focal length of primary mirrors in Fresnel linear collectors

Boito, Paola;
2017-01-01

Abstract

In a linear Fresnel plant adopting slightly curved primary mirrors (cylindrical or parabolic), a significant gain in the collected radiation can be achieved using primary mirrors with different focal lengths, dependent on the position of the mirror with respect to the receiver. This work introduces a universal function that provides the optimal focal length of a mirror, given only the mirror’s position relative to the receiver and the latitude, for a NS-oriented collector with a flat horizontal effective target. In a solar plant with the focal lengths defined by this function, the efficiency gain with respect to a solar field adopting identical mirrors is estimated in the range 1.5–6%, with the gain increasing if mirror imperfections or tracking errors are present: this means that the regulation of the focal lengths is especially useful in containing the loss of efficiency due to defects. The given rule is tolerant to errors in the focal length regulation (up to 10%). The function can be used as a reference for future projects, or as a starting point for more refined optimizations.
2017
Boito, Paola; Grena, Roberto
File in questo prodotto:
File Dimensione Formato  
Paper_fresnel_focal-3.pdf

accesso aperto

Tipologia: Documento in Pre-print
Licenza: Creative commons
Dimensione 199.66 kB
Formato Adobe PDF
199.66 kB Adobe PDF Visualizza/Apri
Boito-Grena__SolarEnergy_2017.pdf

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 428.63 kB
Formato Adobe PDF
428.63 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/892566
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 14
social impact