Purpose: To assess the feasibility of radiological stage-1 ALPPS, associating liver partition and portal vein ligation for staged hepatectomy, by combining portal vein embolization (PVE) with percutaneous intrahepatic split by ablation (PISA). Materials and Methods: Three patients (mean age 65.0 ± 7.3 years) underwent PVE and PISA. PISA was performed 21 days after PVE by microwave ablation to create a continuous intrahepatic cutting plane. Abdominal CT examinations were performed before and after PVE and PISA. The future liver remnant (FLR) volume was calculated by semiautomatic segmentation, and increase was reported as a percentage of the pre-procedural volume. The FLR/body weight (FLR/BW) ratio was calculated; a ratio greater than 0.8% was considered sufficient for guaranteeing adequate liver function after surgery. The liver function before and after PISA was also evaluated by 99mTc-mebrofenin hepatobiliary scintigraphy. Patients’ laboratory tests, performance status, ability to walk were assessed before and after PVE and PISA procedures. Results: No procedure-related complications were recorded. The FLR volume increase in each patient was 42.0, 33.1 and 30.4% within 21 days of PVE and 109.3, 68.1 and 71.7% within 10 days after PISA. The FLR/BW ratios were 0.76, 0.66, 0.63% and 1.13, 0.83, 0.83% after PVE and PISA procedures, respectively. Two patients underwent successful right hepatectomy; in one patient, despite 1.13% FLR/BW, surgery was not performed because of the absolute rejection of blood transfusion due to the patient’s religious convictions. Conclusion: Radiological stage-1 ALPPS is a feasible, minimally invasive option to be further investigated to become an effective alternative to surgical stage-1 ALPPS.

Feasibility of Percutaneous Intrahepatic Split by Microwave Ablation (PISA) After Portal Vein Embolization for Hypertrophy of Future Liver Remnant: The Radiological Stage-1 ALPPS

Cervelli, Rosa;Volterrani, Duccio;Vitali, Saverio;Lombardo, Carlo;LORENZONI, GIULIA;Crocetti, Laura;Campani, Daniela;Cioni, Roberto;Caramella, Davide;Boggi, Ugo
2018-01-01

Abstract

Purpose: To assess the feasibility of radiological stage-1 ALPPS, associating liver partition and portal vein ligation for staged hepatectomy, by combining portal vein embolization (PVE) with percutaneous intrahepatic split by ablation (PISA). Materials and Methods: Three patients (mean age 65.0 ± 7.3 years) underwent PVE and PISA. PISA was performed 21 days after PVE by microwave ablation to create a continuous intrahepatic cutting plane. Abdominal CT examinations were performed before and after PVE and PISA. The future liver remnant (FLR) volume was calculated by semiautomatic segmentation, and increase was reported as a percentage of the pre-procedural volume. The FLR/body weight (FLR/BW) ratio was calculated; a ratio greater than 0.8% was considered sufficient for guaranteeing adequate liver function after surgery. The liver function before and after PISA was also evaluated by 99mTc-mebrofenin hepatobiliary scintigraphy. Patients’ laboratory tests, performance status, ability to walk were assessed before and after PVE and PISA procedures. Results: No procedure-related complications were recorded. The FLR volume increase in each patient was 42.0, 33.1 and 30.4% within 21 days of PVE and 109.3, 68.1 and 71.7% within 10 days after PISA. The FLR/BW ratios were 0.76, 0.66, 0.63% and 1.13, 0.83, 0.83% after PVE and PISA procedures, respectively. Two patients underwent successful right hepatectomy; in one patient, despite 1.13% FLR/BW, surgery was not performed because of the absolute rejection of blood transfusion due to the patient’s religious convictions. Conclusion: Radiological stage-1 ALPPS is a feasible, minimally invasive option to be further investigated to become an effective alternative to surgical stage-1 ALPPS.
2018
Lunardi, Alessandro; Cervelli, Rosa; Volterrani, Duccio; Vitali, Saverio; Lombardo, Carlo; Lorenzoni, Giulia; Crocetti, Laura; Bargellini, Irene; Campani, Daniela; Pollina, Luca Emanuele; Cioni, Roberto; Caramella, Davide; Boggi, Ugo
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/907809
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 9
social impact