The critical distance inverse search procedure, recently proposed by the authors (Santus et al., 2018), was experimentally applied in this work to 42CrMo4+QT steel and 7075-T6 aluminium alloy for fatigue load ratios R = −1 and R = 0.1. The inverse search lengths were in good agreement with the critical distances derived from the crack threshold. The Point Method lengths were higher than the Line Method values since the relatively low stress distribution second derivative. However, this difference is compensated for when the corresponding Method, Point or Line, is then used for the fatigue strength assessment of another specimen or a component. The fatigue predictions and comparisons with the experiments are reported in an accuracy chart, showing that a small radius notched specimen is recommended to determine the critical distance and thus obtain an accurate strength assessment of a blunter specimen. This critical distance determination was then extended to the fatigue finite life, again obtaining accurate predictions, especially for the aluminium alloy. The online version of this paper is provided with MATLAB scripts which contain examples for the critical distance inverse search and the direct problem for the fatigue stress concentration factor calculation.

Experimental determination and sensitivity analysis of the fatigue critical distance obtained with rounded V-notched specimens

C. Santus
;
2018-01-01

Abstract

The critical distance inverse search procedure, recently proposed by the authors (Santus et al., 2018), was experimentally applied in this work to 42CrMo4+QT steel and 7075-T6 aluminium alloy for fatigue load ratios R = −1 and R = 0.1. The inverse search lengths were in good agreement with the critical distances derived from the crack threshold. The Point Method lengths were higher than the Line Method values since the relatively low stress distribution second derivative. However, this difference is compensated for when the corresponding Method, Point or Line, is then used for the fatigue strength assessment of another specimen or a component. The fatigue predictions and comparisons with the experiments are reported in an accuracy chart, showing that a small radius notched specimen is recommended to determine the critical distance and thus obtain an accurate strength assessment of a blunter specimen. This critical distance determination was then extended to the fatigue finite life, again obtaining accurate predictions, especially for the aluminium alloy. The online version of this paper is provided with MATLAB scripts which contain examples for the critical distance inverse search and the direct problem for the fatigue stress concentration factor calculation.
2018
Santus, C.; Taylor, D.; Benedetti, M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/920835
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 55
  • ???jsp.display-item.citation.isi??? 50
social impact