Objective: To determine the usefulness of ultrasound to evaluate central venous catheter misplacements and detection of pneumothorax, thus obviating postprocedural radiograph. After the insertion of a central venous catheter, chest radiograph is usually obtained to ensure correct positioning of the catheter tip and detect postprocedural complications. Design: Prospective observational study. Setting: Adult intensive care unit. Patients: 111 consecutive patients undergoing central venous catheter positioning, using a landmark technique and contrast-enhanced ultrasonography. Measurements and Main Results: A postprocedural chest radiograph was obtained for all patients and was considered as a reference technique. At the end of the procedure, a B-mode ultrasonography was first performed to assess catheter position and detect pneumothorax. Right atrium positioning was detected in 19 patients by ultrasonography, and an additional six by contrast enhanced ultrasonography. Combining ultrasonography and contrast enhanced ultrasonography yielded a 96% sensitivity and 93% specificity in detecting catheter misplacement. Concordance was 95% and κ value was 0.88 (p <.001). Pneumothorax was detected in four patients by ultrasonography and in two by chest radiograph (concordance = 98%). The mean time required to perform ultrasonography plus contrast enhanced ultrasonography was 10 ± 5 mins vs. 83 ± 79 mins for chest radiograph (p <.05). Conclusions: The close concordance between ultrasonography plus contrast enhanced ultrasonography and chest radiograph justifies the use of sonography as a standard technique to ensure the correct positioning of the catheter tip and to detect pneumothorax after central venous catheter cannulation to optimize use of hospital resources and minimize time consumption and radiation. Chest radiograph will be necessary when sonographic examination is impossible to perform by technical limitations. Copyright © 2010 by the Society of Critical Care Medicine and Lippincott Williams & Wilkins.

Ultrasound localization of central vein catheter and detection of postprocedural pneumothorax: An alternative to chest radiography

Corradi, Francesco
Ultimo
Writing – Review & Editing
2010-01-01

Abstract

Objective: To determine the usefulness of ultrasound to evaluate central venous catheter misplacements and detection of pneumothorax, thus obviating postprocedural radiograph. After the insertion of a central venous catheter, chest radiograph is usually obtained to ensure correct positioning of the catheter tip and detect postprocedural complications. Design: Prospective observational study. Setting: Adult intensive care unit. Patients: 111 consecutive patients undergoing central venous catheter positioning, using a landmark technique and contrast-enhanced ultrasonography. Measurements and Main Results: A postprocedural chest radiograph was obtained for all patients and was considered as a reference technique. At the end of the procedure, a B-mode ultrasonography was first performed to assess catheter position and detect pneumothorax. Right atrium positioning was detected in 19 patients by ultrasonography, and an additional six by contrast enhanced ultrasonography. Combining ultrasonography and contrast enhanced ultrasonography yielded a 96% sensitivity and 93% specificity in detecting catheter misplacement. Concordance was 95% and κ value was 0.88 (p <.001). Pneumothorax was detected in four patients by ultrasonography and in two by chest radiograph (concordance = 98%). The mean time required to perform ultrasonography plus contrast enhanced ultrasonography was 10 ± 5 mins vs. 83 ± 79 mins for chest radiograph (p <.05). Conclusions: The close concordance between ultrasonography plus contrast enhanced ultrasonography and chest radiograph justifies the use of sonography as a standard technique to ensure the correct positioning of the catheter tip and to detect pneumothorax after central venous catheter cannulation to optimize use of hospital resources and minimize time consumption and radiation. Chest radiograph will be necessary when sonographic examination is impossible to perform by technical limitations. Copyright © 2010 by the Society of Critical Care Medicine and Lippincott Williams & Wilkins.
2010
Vezzani, Antonella; Brusasco, Claudia; Palermo, Salvatore; Launo, Claudio; Mergoni, Mario; Corradi, Francesco
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/935098
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 144
  • ???jsp.display-item.citation.isi??? 124
social impact