Purpose: The aim of this study was to compare the success rate and safety of short-axis versus long-axis approaches to ultrasound-guided subclavian vein cannulation. Methods: A total of 190 patients requiring central venous cannulation following cardiac surgery were randomized to either short-axis or long-axis ultrasound-guided cannulation of the subclavian vein. Each cannulation was performed by anesthesiologists with at least 3 years’ experience of ultrasound-guided central vein cannulation (>150 procedures/year, 50% short-axis and 50% long-axis). Success rate, insertion time, number of needle redirections, number of separate skin or vessel punctures, rate of mechanical complications, catheter misplacements, and incidence of central line-associated bloodstream infection were documented for each procedure. Results: The subclavian vein was successfully cannulated in all 190 patients. The mean insertion time was significantly shorter (p = 0.040) in the short-axis group (69 ± 74 s) than in the long-axis group (98 ± 103 s). The short-axis group was also associated with a higher overall success rate (96 vs. 78%, p < 0.001), first-puncture success rate (86 vs. 67%, p = 0.003), and first-puncture single-pass success rate (72 vs. 48%, p = 0.002), and with fewer needle redirections (0.39 ± 0.88 vs. 0.88 ± 1.15, p = 0.001), skin punctures (1.12 ± 0.38 vs. 1.28 ± 0.54, p = 0.019), and complications (3 vs. 13%, p = 0.028). Conclusions: The short-axis procedure for ultrasound-guided subclavian cannulation offers advantages over the long-axis approach in cardiac surgery patients.

A randomized clinical trial of ultrasound-guided infra-clavicular cannulation of the subclavian vein in cardiac surgical patients: short-axis versus long-axis approach

Corradi, Francesco
Ultimo
Writing – Review & Editing
2017-01-01

Abstract

Purpose: The aim of this study was to compare the success rate and safety of short-axis versus long-axis approaches to ultrasound-guided subclavian vein cannulation. Methods: A total of 190 patients requiring central venous cannulation following cardiac surgery were randomized to either short-axis or long-axis ultrasound-guided cannulation of the subclavian vein. Each cannulation was performed by anesthesiologists with at least 3 years’ experience of ultrasound-guided central vein cannulation (>150 procedures/year, 50% short-axis and 50% long-axis). Success rate, insertion time, number of needle redirections, number of separate skin or vessel punctures, rate of mechanical complications, catheter misplacements, and incidence of central line-associated bloodstream infection were documented for each procedure. Results: The subclavian vein was successfully cannulated in all 190 patients. The mean insertion time was significantly shorter (p = 0.040) in the short-axis group (69 ± 74 s) than in the long-axis group (98 ± 103 s). The short-axis group was also associated with a higher overall success rate (96 vs. 78%, p < 0.001), first-puncture success rate (86 vs. 67%, p = 0.003), and first-puncture single-pass success rate (72 vs. 48%, p = 0.002), and with fewer needle redirections (0.39 ± 0.88 vs. 0.88 ± 1.15, p = 0.001), skin punctures (1.12 ± 0.38 vs. 1.28 ± 0.54, p = 0.019), and complications (3 vs. 13%, p = 0.028). Conclusions: The short-axis procedure for ultrasound-guided subclavian cannulation offers advantages over the long-axis approach in cardiac surgery patients.
2017
Vezzani, Antonella; Manca, Tullio; Brusasco, Claudia; Santori, Gregorio; Cantadori, Luca; Ramelli, Andrea; Gonzi, Gianluca; Nicolini, Francesco; Gherli, Tiziano; Corradi, Francesco
File in questo prodotto:
File Dimensione Formato  
Intensive Care Medicine 2017 Official.pdf

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.2 MB
Formato Adobe PDF
1.2 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/935100
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 31
social impact