In seismic zones, suitable procedures to assess the seismic vulnerability of existing buildings are necessary also in view of optimal planning of interventions. Starting from the agreement between the Municipality of Florence and the Department of Civil and Industrial Engineering of the University of Pisa, a research program is ongoing, devoted to setup a simplified, fast but reliable procedure for the evaluation of seismic performance of masonry buildings. In this paper, a simplified non-linear pushover type method for the verification of unreinforced multi-story masonry buildings with both deformable and non-deformable slabs is presented, starting from some of the basic assumptions of the POR method. Various tests on the procedure show that the method is able to give results that are comparable with those obtained by the classical pushover analysis performed on equivalent frame models. The intuitiveness of the method and the low computational effort required by the new algorithm allow the evaluation of the sensitivity of non-linear static analysis regarding the definition of mechanical parameters. In particular, the relevant influence of the modulus of elasticity as well as the ultimate inter-story displacement assumed for masonry walls on the assessment of seismic performance are discussed in detail.The results are presented for a significant case study, the Primary School “G. Carducci” in Florence, a four-story masonry building, with a horseshoe layout where lateral appendixes detached from the central block.

Influence of mechanical parameters on non-linear static analysis of masonry buildings: a relevant case-study

Croce, Pietro;Formichi, Paolo;Landi, Filippo;
2018-01-01

Abstract

In seismic zones, suitable procedures to assess the seismic vulnerability of existing buildings are necessary also in view of optimal planning of interventions. Starting from the agreement between the Municipality of Florence and the Department of Civil and Industrial Engineering of the University of Pisa, a research program is ongoing, devoted to setup a simplified, fast but reliable procedure for the evaluation of seismic performance of masonry buildings. In this paper, a simplified non-linear pushover type method for the verification of unreinforced multi-story masonry buildings with both deformable and non-deformable slabs is presented, starting from some of the basic assumptions of the POR method. Various tests on the procedure show that the method is able to give results that are comparable with those obtained by the classical pushover analysis performed on equivalent frame models. The intuitiveness of the method and the low computational effort required by the new algorithm allow the evaluation of the sensitivity of non-linear static analysis regarding the definition of mechanical parameters. In particular, the relevant influence of the modulus of elasticity as well as the ultimate inter-story displacement assumed for masonry walls on the assessment of seismic performance are discussed in detail.The results are presented for a significant case study, the Primary School “G. Carducci” in Florence, a four-story masonry building, with a horseshoe layout where lateral appendixes detached from the central block.
2018
Croce, Pietro; Beconcini, Maria Luisa; Formichi, Paolo; Cioni, Paolo; Landi, Filippo; Mochi, Caterina; Giuri, Riccardo
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S2452321618301446-Mechanical.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Versione finale editoriale
Licenza: Creative commons
Dimensione 785.85 kB
Formato Adobe PDF
785.85 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/942055
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 12
social impact