Guided Wave (GW) testing is regularly used for finding defect locations through long range screening using low-frequency waves (from 5 to 250 kHz) [1]-[3]. Magnetostrictive sensors can overcome some issues, which usually limit the application to Nuclear Power Plants (NPPs) [4], like for example, high temperatures [5]-[6], high wall thickness of components in the primary circuit, and characteristic defect typologies. The authors have already shown the basic theoretical background, some simulations and some first experimental results concerning a real steel pipe, used for steam discharge, having a complex structure. Collecting more experimental data with a novel test campaign on the same pipe its complex structure results as a useful benchmark for the application of GWs as Non Destructive Techniques (NDT). Experimental measures using a symmetrical probe and a local probe in different configurations (pulse-echo and pitch-catch) indicate that GW testing with magnetostrictive sensors can be reliably applied to long-term monitoring of NPP components.

Guided waves as an online monitoring technology for long term operation in NPPS: New experimental results on a steam discharge pipe

Bertoncini, Francesco;Raugi, Marco
2017-01-01

Abstract

Guided Wave (GW) testing is regularly used for finding defect locations through long range screening using low-frequency waves (from 5 to 250 kHz) [1]-[3]. Magnetostrictive sensors can overcome some issues, which usually limit the application to Nuclear Power Plants (NPPs) [4], like for example, high temperatures [5]-[6], high wall thickness of components in the primary circuit, and characteristic defect typologies. The authors have already shown the basic theoretical background, some simulations and some first experimental results concerning a real steel pipe, used for steam discharge, having a complex structure. Collecting more experimental data with a novel test campaign on the same pipe its complex structure results as a useful benchmark for the application of GWs as Non Destructive Techniques (NDT). Experimental measures using a symmetrical probe and a local probe in different configurations (pulse-echo and pitch-catch) indicate that GW testing with magnetostrictive sensors can be reliably applied to long-term monitoring of NPP components.
2017
9784888982566
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/951639
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact