During at-speed test of high performance sequential ICs using scan-based Logic BIST, the IC activity factor (AF) induced by the applied test vectors is significantly higher than that experienced during its in field operation. Consequently, power droop (PD) may take place during both shift and capture phases, which will slow down the circuit under test (CUT) signal transitions. At capture, this phenomenon is likely to be erroneously recognized as due to delay faults. As a result, a false test fail may be generated, with consequent increase in yield loss. In this paper, we propose two approaches to reduce the PD generated at capture during at-speed test of sequential circuits with scan-based Logic BIST using the Launch-On-Shift scheme. Both approaches increase the correlation between adjacent bits of the scan chains with respect to conventional scan-based LBIST. This way, the AF of the scan chains at capture is reduced. Consequently, the AF of the CUT at capture, thus the PD at capture, is also reduced compared to conventional scan-based LBIST. The former approach, hereinafter referred to as Low-Cost Approach (LCA), enables a 50 percent reduction in the worst case magnitude of PD during conventional logic BIST. It requires a small cost in terms of area overhead (of approximately 1.5 percent on average), and it does not increase the number of test vectors over the conventional scan-based LBIST to achieve the same Fault Coverage (FC). Moreover, compared to three recent alternative solutions, LCA features a comparable AF in the scan chains at capture, while requiring lower test time and area overhead. The second approach, hereinafter referred to as High-Reduction Approach (HRA), enables scalable PD reductions at capture of up to 87 percent, with limited additional costs in terms of area overhead and number of required test vectors for a given target FC, over our LCA approach. Particularly, compared to two of the three recent alternative solutions mentioned above, HRA enables a significantly lower AF in the scan chains during the application of test vectors, while requiring either a comparable area overhead or a significantly lower test time. Compared to the remaining alternative solutions mentioned above, HRA enables a similar AF in the scan chains at capture (approximately 90 percent lower than conventional scan-based LBIST), while requiring a significantly lower test time (approximately 4.87 times on average lower number of test vectors) and comparable area overhead (of approximately 1.9 percent on average).

Low-Cost and High-Reduction Approaches for Power Droop during Launch-On-Shift Scan-Based Logic BIST

Rossi D.;
2016-01-01

Abstract

During at-speed test of high performance sequential ICs using scan-based Logic BIST, the IC activity factor (AF) induced by the applied test vectors is significantly higher than that experienced during its in field operation. Consequently, power droop (PD) may take place during both shift and capture phases, which will slow down the circuit under test (CUT) signal transitions. At capture, this phenomenon is likely to be erroneously recognized as due to delay faults. As a result, a false test fail may be generated, with consequent increase in yield loss. In this paper, we propose two approaches to reduce the PD generated at capture during at-speed test of sequential circuits with scan-based Logic BIST using the Launch-On-Shift scheme. Both approaches increase the correlation between adjacent bits of the scan chains with respect to conventional scan-based LBIST. This way, the AF of the scan chains at capture is reduced. Consequently, the AF of the CUT at capture, thus the PD at capture, is also reduced compared to conventional scan-based LBIST. The former approach, hereinafter referred to as Low-Cost Approach (LCA), enables a 50 percent reduction in the worst case magnitude of PD during conventional logic BIST. It requires a small cost in terms of area overhead (of approximately 1.5 percent on average), and it does not increase the number of test vectors over the conventional scan-based LBIST to achieve the same Fault Coverage (FC). Moreover, compared to three recent alternative solutions, LCA features a comparable AF in the scan chains at capture, while requiring lower test time and area overhead. The second approach, hereinafter referred to as High-Reduction Approach (HRA), enables scalable PD reductions at capture of up to 87 percent, with limited additional costs in terms of area overhead and number of required test vectors for a given target FC, over our LCA approach. Particularly, compared to two of the three recent alternative solutions mentioned above, HRA enables a significantly lower AF in the scan chains during the application of test vectors, while requiring either a comparable area overhead or a significantly lower test time. Compared to the remaining alternative solutions mentioned above, HRA enables a similar AF in the scan chains at capture (approximately 90 percent lower than conventional scan-based LBIST), while requiring a significantly lower test time (approximately 4.87 times on average lower number of test vectors) and comparable area overhead (of approximately 1.9 percent on average).
2016
Omana, M.; Rossi, D.; Beniamino, E.; Metra, C.; Tirumurti, C.; Galivanche, R.
File in questo prodotto:
File Dimensione Formato  
Accepted_Manuscript_1025936.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.13 MB
Formato Adobe PDF
1.13 MB Adobe PDF Visualizza/Apri
07296618.pdf

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.01 MB
Formato Adobe PDF
1.01 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1025936
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact