In this paper, we show that clock faults producing duty-cycle variations, which have been proven very likely, can give rise to min or max delay violations. This mandates new, specific testing approaches for clock faults, to avoid them to compromise the system correct operation in the field, with dramatic effects on product quality and defect level. We then introduce a new scheme that can be employed to detect the clock faults causing duty-cycle variations. © 2013 Springer Science+Business Media New York.

Clock faults induced min and max delay violations

Rossi D.
;
2014-01-01

Abstract

In this paper, we show that clock faults producing duty-cycle variations, which have been proven very likely, can give rise to min or max delay violations. This mandates new, specific testing approaches for clock faults, to avoid them to compromise the system correct operation in the field, with dramatic effects on product quality and defect level. We then introduce a new scheme that can be employed to detect the clock faults causing duty-cycle variations. © 2013 Springer Science+Business Media New York.
2014
Rossi, D.; Omana, M.; Cazeaux, J. M.; Metra, C.; Mak, T. M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1025967
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact