The aim was to assess 3-year longitudinal data using 6MWT in 26 ambulant boys affected by DMD carrying nonsense mutations and to compare their results to other small mutations. We also wished to establish, within the nonsense mutations group, patterns of change according to several variables. Patients with nonsense mutations were categorized according to the stop codon type newly created by the mutation and also including the adjacent 5′ (upstream) and 3′ (downstream) nucleotides. No significant difference was found between nonsense mutations and other small mutations (p > 0.05) on the 6MWT. Within the nonsense mutations group, there was no difference in 6MWT when the patients were subdivided according to: Type of stop codon, frame status of exons involved, protein domain affected. In contrast, there was a difference when the stop codon together with the 3′ adjacent nucleotide (“stop+4 model”) was considered (p < 0.05) with patients with stop codon TGA and 3′ adjacent nucleotide G (TGAG) having a more rapid decline. Our finding suggest that the stop+4 model may help in predicting functional changes. This data will be useful at the time of interpreting the long term follow up of patients treated with Ataluren that are becoming increasingly available.

The nonsense mutation stop+4 model correlates with motor changes in Duchenne muscular dystrophy

Battini R.
;
2021-01-01

Abstract

The aim was to assess 3-year longitudinal data using 6MWT in 26 ambulant boys affected by DMD carrying nonsense mutations and to compare their results to other small mutations. We also wished to establish, within the nonsense mutations group, patterns of change according to several variables. Patients with nonsense mutations were categorized according to the stop codon type newly created by the mutation and also including the adjacent 5′ (upstream) and 3′ (downstream) nucleotides. No significant difference was found between nonsense mutations and other small mutations (p > 0.05) on the 6MWT. Within the nonsense mutations group, there was no difference in 6MWT when the patients were subdivided according to: Type of stop codon, frame status of exons involved, protein domain affected. In contrast, there was a difference when the stop codon together with the 3′ adjacent nucleotide (“stop+4 model”) was considered (p < 0.05) with patients with stop codon TGA and 3′ adjacent nucleotide G (TGAG) having a more rapid decline. Our finding suggest that the stop+4 model may help in predicting functional changes. This data will be useful at the time of interpreting the long term follow up of patients treated with Ataluren that are becoming increasingly available.
2021
Brogna, C.; Coratti, G.; Rossi, R.; Neri, M.; Messina, S.; Amico, A. D.; Bruno, C.; Lucibello, S.; Vita, G.; Berardinelli, A.; Magri, F.; Ricci, F.; P...espandi
File in questo prodotto:
File Dimensione Formato  
art-14.pdf

non disponibili

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - accesso privato/ristretto
Dimensione 1.6 MB
Formato Adobe PDF
1.6 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1116259
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact