The aim was to assess 3-year longitudinal data using 6MWT in 26 ambulant boys affected by DMD carrying nonsense mutations and to compare their results to other small mutations. We also wished to establish, within the nonsense mutations group, patterns of change according to several variables. Patients with nonsense mutations were categorized according to the stop codon type newly created by the mutation and also including the adjacent 5′ (upstream) and 3′ (downstream) nucleotides. No significant difference was found between nonsense mutations and other small mutations (p > 0.05) on the 6MWT. Within the nonsense mutations group, there was no difference in 6MWT when the patients were subdivided according to: Type of stop codon, frame status of exons involved, protein domain affected. In contrast, there was a difference when the stop codon together with the 3′ adjacent nucleotide (“stop+4 model”) was considered (p < 0.05) with patients with stop codon TGA and 3′ adjacent nucleotide G (TGAG) having a more rapid decline. Our finding suggest that the stop+4 model may help in predicting functional changes. This data will be useful at the time of interpreting the long term follow up of patients treated with Ataluren that are becoming increasingly available.
The nonsense mutation stop+4 model correlates with motor changes in Duchenne muscular dystrophy
Battini R.
;
2021-01-01
Abstract
The aim was to assess 3-year longitudinal data using 6MWT in 26 ambulant boys affected by DMD carrying nonsense mutations and to compare their results to other small mutations. We also wished to establish, within the nonsense mutations group, patterns of change according to several variables. Patients with nonsense mutations were categorized according to the stop codon type newly created by the mutation and also including the adjacent 5′ (upstream) and 3′ (downstream) nucleotides. No significant difference was found between nonsense mutations and other small mutations (p > 0.05) on the 6MWT. Within the nonsense mutations group, there was no difference in 6MWT when the patients were subdivided according to: Type of stop codon, frame status of exons involved, protein domain affected. In contrast, there was a difference when the stop codon together with the 3′ adjacent nucleotide (“stop+4 model”) was considered (p < 0.05) with patients with stop codon TGA and 3′ adjacent nucleotide G (TGAG) having a more rapid decline. Our finding suggest that the stop+4 model may help in predicting functional changes. This data will be useful at the time of interpreting the long term follow up of patients treated with Ataluren that are becoming increasingly available.File | Dimensione | Formato | |
---|---|---|---|
art-14.pdf
non disponibili
Tipologia:
Versione finale editoriale
Licenza:
NON PUBBLICO - accesso privato/ristretto
Dimensione
1.6 MB
Formato
Adobe PDF
|
1.6 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.