The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: (1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; (2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of 200MHz with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of 20krads, neutron flux of 1012n(1MeVeq)∕cm2, magnetic field of 1T and in vacuum level of 10−4Torr. A description of the readout system and qualification tests is reported.

Mu2e calorimeter readout system

Caiulo D.;Cei F.;D'Errico F.;Donati S.;Faetti S.;Giudici S.;Lazzeri L.;Nicolo D.;Pezzullo G.;Polacco G.;Sozzi M.;
2019-01-01

Abstract

The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: (1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; (2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of 200MHz with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of 20krads, neutron flux of 1012n(1MeVeq)∕cm2, magnetic field of 1T and in vacuum level of 10−4Torr. A description of the readout system and qualification tests is reported.
2019
Atanov, N.; Baranov, V.; Baldini, L.; Budagov, J.; Caiulo, D.; Cei, F.; Cervelli, F.; Colao, F.; Cordelli, M.; Corradi, G.; Davydov, Y. I.; D'Errico, F.; Di Falco, S.; Diociaiuti, E.; Donati, S.; Donghia, R.; Echenard, B.; Faetti, S.; Giovannella, S.; Giudici, S.; Glagolev, V.; Grancagnolo, F.; Happacher, F.; Hitlin, D. G.; Lazzeri, L.; Martini, M.; Miscetti, S.; Miyashita, T.; Morescalchi, L.; Murat, P.; Nicolo, D.; Pedreschi, E.; Pezzullo, G.; Polacco, G.; Porter, F.; Raffaelli, F.; Ricci, M.; Saputi, A.; Sarra, I.; Sozzi, M.; Spinella, F.; Tassielli, G.; Tereshchenko, V.; Usubov, Z.; Vasilyev, I. I.; Zhu, R. Y.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1124166
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact