The aim was to evaluate the use of a bovine procalcitonin (PCT) ELISA kit (Cusabio, China) for assessing PCT in bovine milk samples. Validation was performed by using 10 plasma and corresponding milk samples from mastitic cows. The limit of detection (LOD) was calculated. The coefficient of variation (CV%) of the readings of five plasma samples measured five times in the same plate (intra-assay) and the CV% of the same five samples read five times in three separate plates was evaluated. Parallelism was determined by serial twofold dilutions of five plasma and corresponding milk samples. Milk samples were analyzed with and without centrifugation. Regarding plasma PCT, the method presented an inter- and intra-CV < 23.7% and parallelism had very good recovery values. The ELISA kit studied can measure bovine plasma PCT concentrations. The kit antibodies fail in binding PCT in milk samples because all centrifuged milk samples showed a lower LOD than blank samples. Only three uncentrifuged milk samples showed measurable PCT concentrations. Due to these results, the commercial ELISA kit investigated could not be employed for the detection of PCT in milk samples.

Can Procalcitonin Be Dosed in Bovine Milk Using a Commercial ELISA Kit?

Valentina Meucci
Primo
;
Chiara Orsetti
Secondo
;
Micaela Sgorbini;Federica Battaglia;Francesca Bonelli
Ultimo
2022-01-01

Abstract

The aim was to evaluate the use of a bovine procalcitonin (PCT) ELISA kit (Cusabio, China) for assessing PCT in bovine milk samples. Validation was performed by using 10 plasma and corresponding milk samples from mastitic cows. The limit of detection (LOD) was calculated. The coefficient of variation (CV%) of the readings of five plasma samples measured five times in the same plate (intra-assay) and the CV% of the same five samples read five times in three separate plates was evaluated. Parallelism was determined by serial twofold dilutions of five plasma and corresponding milk samples. Milk samples were analyzed with and without centrifugation. Regarding plasma PCT, the method presented an inter- and intra-CV < 23.7% and parallelism had very good recovery values. The ELISA kit studied can measure bovine plasma PCT concentrations. The kit antibodies fail in binding PCT in milk samples because all centrifuged milk samples showed a lower LOD than blank samples. Only three uncentrifuged milk samples showed measurable PCT concentrations. Due to these results, the commercial ELISA kit investigated could not be employed for the detection of PCT in milk samples.
2022
Meucci, Valentina; Orsetti, Chiara; Sgorbini, Micaela; Battaglia, Federica; Cresci, Marta; Bonelli, Francesca
File in questo prodotto:
File Dimensione Formato  
animals-12-00289.pdf

accesso aperto

Tipologia: Versione finale editoriale
Licenza: Creative commons
Dimensione 229.96 kB
Formato Adobe PDF
229.96 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1125339
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact