This work aimed to compare the non-intrusive Rayleigh scattering technique and intrusive suction pyrometry for temperature measurements in a semi-industrial MILD combustion furnace. The temperature trends obtained with the two measurement techniques were consistent. However, in the zone characterized by the jet development and the mixing process between the reactants and the recirculated burnt gases, laser-based measurements brought different temperature values, which compared favorably with model predictions. CFD simulations were used to shed light on the disturbances induced by the suction pyrometer and their impact on the fluid dynamics field. It was found that the suction pyrometer disrupts the flow inside the furnace, leading to an asymmetry of the system. In addition, the temperature measured using the suction probe is an average over the sucked volume which itself is variable in nature as, for a given suction volumetric flow rate, the sucked volume depends on the local mixture velocity and density. The present analysis can help reconcile inconsistencies found in CFD modeling in which probe sampling measurements were used for validation.

A combined experimental, numerical, and data consistency approach for the characterization of temperature distribution in a MILD combustion furnace

Galletti, Chiara;
2024-01-01

Abstract

This work aimed to compare the non-intrusive Rayleigh scattering technique and intrusive suction pyrometry for temperature measurements in a semi-industrial MILD combustion furnace. The temperature trends obtained with the two measurement techniques were consistent. However, in the zone characterized by the jet development and the mixing process between the reactants and the recirculated burnt gases, laser-based measurements brought different temperature values, which compared favorably with model predictions. CFD simulations were used to shed light on the disturbances induced by the suction pyrometer and their impact on the fluid dynamics field. It was found that the suction pyrometer disrupts the flow inside the furnace, leading to an asymmetry of the system. In addition, the temperature measured using the suction probe is an average over the sucked volume which itself is variable in nature as, for a given suction volumetric flow rate, the sucked volume depends on the local mixture velocity and density. The present analysis can help reconcile inconsistencies found in CFD modeling in which probe sampling measurements were used for validation.
2024
Lubrano Lavadera, Marco; Mustafa Kamal, M.; Sharma, Saurabh; Donato, Laura; Galletti, Chiara; Coussement, Axel; Parente, Alessandro
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1252828
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact