In this study, we present a wearable sensing system for monitoring the physiological status of damaged biological tissues based on a flexible, frequency-coded electromagnetic spiral resonator array. The physiological parameter evaluation is performed in a contactless way, avoiding the placing of electronically active elements directly upon the patient’s skin, thus ensuring safety and comfort. Firstly, we report in detail the physical principles behind the sensing strategy: a passive array is interrogated through an actively fed external single-loop probe that is inductively coupled with the double-layer spiral unit cells. The variation in the physiological parameters influences the array response, thus providing sensing information, due to the different complex dielectric permittivity values related to the tissue status. Moreover, the proposed frequency-coded approach allows for spatial information on the lesion to be retrieved, thus increasing the sensing ability. In order to prove the validity of this general methodology, we created a numerical test case, designing a practical implementation of the wearable sensing system working at a radiofrequency regime (10–100 MHz). In addition, we also fabricated prototypes, exploiting PCB technology, and realized stratified phantoms by incorporating opportune additives to control the dielectric properties. The numerical results and the experimental verification demonstrated the validity of the developed sensing strategy, showing satisfying agreement and, thus, proving the good sensibility and spatial resolution of the frequency-coded array. These results can open the path to a radically novel approach for self-care and monitoring of inflamed status and, more generally, for wearable sensing devices in biomedical applications.
A Flexible Frequency-Coded Electromagnetic Sensing Array for Contactless Biological Tissues Health Monitoring
Masi, Angelica;Brizi, Danilo;Canicattì, Eliana;Monorchio, Agostino
2025-01-01
Abstract
In this study, we present a wearable sensing system for monitoring the physiological status of damaged biological tissues based on a flexible, frequency-coded electromagnetic spiral resonator array. The physiological parameter evaluation is performed in a contactless way, avoiding the placing of electronically active elements directly upon the patient’s skin, thus ensuring safety and comfort. Firstly, we report in detail the physical principles behind the sensing strategy: a passive array is interrogated through an actively fed external single-loop probe that is inductively coupled with the double-layer spiral unit cells. The variation in the physiological parameters influences the array response, thus providing sensing information, due to the different complex dielectric permittivity values related to the tissue status. Moreover, the proposed frequency-coded approach allows for spatial information on the lesion to be retrieved, thus increasing the sensing ability. In order to prove the validity of this general methodology, we created a numerical test case, designing a practical implementation of the wearable sensing system working at a radiofrequency regime (10–100 MHz). In addition, we also fabricated prototypes, exploiting PCB technology, and realized stratified phantoms by incorporating opportune additives to control the dielectric properties. The numerical results and the experimental verification demonstrated the validity of the developed sensing strategy, showing satisfying agreement and, thus, proving the good sensibility and spatial resolution of the frequency-coded array. These results can open the path to a radically novel approach for self-care and monitoring of inflamed status and, more generally, for wearable sensing devices in biomedical applications.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.