Previous studies suggest a delay of pattern visual evoked potentials (PVEPs) in multiple sclerosis (MS) depending on grating orientation. We examined a group of 14 patients with definite MS recording PVEPs to vertical and horizontal grating and analysing latency and amplitude of P60, N70 and P100 waves. We evaluated contrast sensitivity (CS) to dark and bright bars of several spatial frequencies (SF). The aim was to evaluate the diagnostic value of evoked responses and CS in revealing involvement of cortical structures. PVEPs to 1 degrees cycle/degree (c/d) vertical bars were abnormal in 25% for P60, in 32% for N70 and in 36%, for P100; in 25%, 36% and 42% respectively at 4 c/d; as regards horizontal bars at 1 c/d we found alterations of P60, N70 and P100 in 11%, 19% and 27% respectively; at 4 c/d in 19%, 27%) and 35%. CS resulted more abnormal for vertical grating, with a maximum impairment for 3.7 c/d SF. We may conclude that the use of vertical grating in clinical routine is more reliable both for PVEPs and CS testing; in addition CS can be abnormal even with normal PVEPs: this could mean an early impairment of CS and provide useful indications about a subclinical involvement of visual cortex.

Effects of grating spatial orientation on visual evoked potentials and contrast sensitivity in multiple sclerosis

BONFIGLIO L;SICILIANO, GABRIELE;SARTUCCI, FERDINANDO
2001-01-01

Abstract

Previous studies suggest a delay of pattern visual evoked potentials (PVEPs) in multiple sclerosis (MS) depending on grating orientation. We examined a group of 14 patients with definite MS recording PVEPs to vertical and horizontal grating and analysing latency and amplitude of P60, N70 and P100 waves. We evaluated contrast sensitivity (CS) to dark and bright bars of several spatial frequencies (SF). The aim was to evaluate the diagnostic value of evoked responses and CS in revealing involvement of cortical structures. PVEPs to 1 degrees cycle/degree (c/d) vertical bars were abnormal in 25% for P60, in 32% for N70 and in 36%, for P100; in 25%, 36% and 42% respectively at 4 c/d; as regards horizontal bars at 1 c/d we found alterations of P60, N70 and P100 in 11%, 19% and 27% respectively; at 4 c/d in 19%, 27%) and 35%. CS resulted more abnormal for vertical grating, with a maximum impairment for 3.7 c/d SF. We may conclude that the use of vertical grating in clinical routine is more reliable both for PVEPs and CS testing; in addition CS can be abnormal even with normal PVEPs: this could mean an early impairment of CS and provide useful indications about a subclinical involvement of visual cortex.
2001
Logi, F; Pellegrinetti, A; Bonfiglio, L; Baglini, O; Siciliano, Gabriele; Ludice, A; Sartucci, Ferdinando
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/178542
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? ND
social impact