The present study developed a validate and precise reversed-phase high performance liquid chromatography (HPLC) method for the determination of thalidomide (T) in plasma, to quantify T in patients affected by hepatocellular carcinoma. Twelve male subjects aging from 62 to 82 years and weighting 66-88kg, were orally administered with single dose of T (200mg/BW). Two ml of stabilizer-solution (CH3OH/CH3CN, 1/1 (v/v)+CH3COOH 2%) were added to 1ml of human plasma and stoked to -80 degrees C until analyses. This moisture (1.38microl) was added with 20microl of CF3COOH and 100microl of phthalimide (IS) 1.75microg/ml, vortexed and centrifuged. Surnatant (800microl) was dried under vacuum at room temperature, added with 50microl of appropriate solution and injected onto HPLC. T and IS were detected at UV wavelength of 220nm with a run time of 10min. Mobile phase was 10mM pH 5.5NH4+CH3COO-/CH3CN, 75/25 (v/v) buffer at flow rate of 1.5ml/min. Inter-day and intra-day variation coefficient was <10% with an error of accuracy <10%. The present detection method was able to quantify T to every withdrawal time period (LOD 0.05microg/ml). The IS used in the present study had the same wavelength maximum absorption of T, differently from early UV detection methods reported in literature where phenacetin was used. Pharmacokinetic parameters belonging from the present study are not significantly different from those calculated in previously studies performed in human health subjects and patients affected by other pathology.

HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF THALIDOMIDE IN PATIENTS AFFECTED BY HEPATOCELLULAR CARCINOMA

SACCOMANNI, GIUSEPPE;MANERA, CLEMENTINA;GIORGI, MARIO;MACCHIA, MARCO
2008-01-01

Abstract

The present study developed a validate and precise reversed-phase high performance liquid chromatography (HPLC) method for the determination of thalidomide (T) in plasma, to quantify T in patients affected by hepatocellular carcinoma. Twelve male subjects aging from 62 to 82 years and weighting 66-88kg, were orally administered with single dose of T (200mg/BW). Two ml of stabilizer-solution (CH3OH/CH3CN, 1/1 (v/v)+CH3COOH 2%) were added to 1ml of human plasma and stoked to -80 degrees C until analyses. This moisture (1.38microl) was added with 20microl of CF3COOH and 100microl of phthalimide (IS) 1.75microg/ml, vortexed and centrifuged. Surnatant (800microl) was dried under vacuum at room temperature, added with 50microl of appropriate solution and injected onto HPLC. T and IS were detected at UV wavelength of 220nm with a run time of 10min. Mobile phase was 10mM pH 5.5NH4+CH3COO-/CH3CN, 75/25 (v/v) buffer at flow rate of 1.5ml/min. Inter-day and intra-day variation coefficient was <10% with an error of accuracy <10%. The present detection method was able to quantify T to every withdrawal time period (LOD 0.05microg/ml). The IS used in the present study had the same wavelength maximum absorption of T, differently from early UV detection methods reported in literature where phenacetin was used. Pharmacokinetic parameters belonging from the present study are not significantly different from those calculated in previously studies performed in human health subjects and patients affected by other pathology.
2008
Saccomanni, Giuseppe; Turini, V; Manera, Clementina; Placanica, G; OMODEO SALÈ, E; Jemos, C; Giorgi, Mario; Macchia, Marco
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/180562
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact