The use of biodegradable polymers for drug delivery systems excluded the need for a second operation to remove the carrier. However, the development of an avascular fibrous capsule, reducing drug release, has raised concern about these polymers in terms of tissue-implant reaction. Five novel polymers were evaluated in vivo after implantation in the rat dorsal subcutis and compared to the reference polycaprolactone (PCL). Poly(cyclohexyl-sebacate) (PCS), poly(L-lactide-b-1,5-dioxepan-2-one-b-L-lactide) (PLLA-PDXO-PLLA), two 3-hydroxybutyrate-co-3-hydroxyvalerate copolymers (D400G and D600G), and a poly(organo)phosphazene (POS-PheOEt:Imidazole) specimens were histologically evaluated in terms of the inflammatory tissue thickness and vascular density at 4 and 12 weeks from surgery. The highest values of inflammatory tissue thickness were observed in D600G (P < 0.01), PCS (P < 0.001) and PLLA-PDXO-PLLA (P < 0.001) at 4 weeks, while POP-PheOEt:Imidazole showed the lowest value of inflammatory tissue thickness (P < 0.05) at 12 weeks. D400G, D600G, PLLA-PDXO-PPLA and POP-PheOEt:Imidazole showed higher (P < 0.001) values of vascular density near the implants in comparison to PCL at 4 weeks. Finally, D400G and D600G increased their vessel densities while POP-PheOEt:Imidazole and the synthetic polyester PLLA-PDXO-PLLA presented similar vessel density values during experimental times. These different behaviours to improve neoangiogenesis without severe inflammatory tissue-responses could be further investigated with drugs in order to obtain time-programmable drug delivery systems for musculoskeletal therapy

New polymers for drug delivery systems in orthopaedics: in vivo biocompatibility evaluation

NICOLINI, ANDREA;CARPI, ANGELO;
2004-01-01

Abstract

The use of biodegradable polymers for drug delivery systems excluded the need for a second operation to remove the carrier. However, the development of an avascular fibrous capsule, reducing drug release, has raised concern about these polymers in terms of tissue-implant reaction. Five novel polymers were evaluated in vivo after implantation in the rat dorsal subcutis and compared to the reference polycaprolactone (PCL). Poly(cyclohexyl-sebacate) (PCS), poly(L-lactide-b-1,5-dioxepan-2-one-b-L-lactide) (PLLA-PDXO-PLLA), two 3-hydroxybutyrate-co-3-hydroxyvalerate copolymers (D400G and D600G), and a poly(organo)phosphazene (POS-PheOEt:Imidazole) specimens were histologically evaluated in terms of the inflammatory tissue thickness and vascular density at 4 and 12 weeks from surgery. The highest values of inflammatory tissue thickness were observed in D600G (P < 0.01), PCS (P < 0.001) and PLLA-PDXO-PLLA (P < 0.001) at 4 weeks, while POP-PheOEt:Imidazole showed the lowest value of inflammatory tissue thickness (P < 0.05) at 12 weeks. D400G, D600G, PLLA-PDXO-PPLA and POP-PheOEt:Imidazole showed higher (P < 0.001) values of vascular density near the implants in comparison to PCL at 4 weeks. Finally, D400G and D600G increased their vessel densities while POP-PheOEt:Imidazole and the synthetic polyester PLLA-PDXO-PLLA presented similar vessel density values during experimental times. These different behaviours to improve neoangiogenesis without severe inflammatory tissue-responses could be further investigated with drugs in order to obtain time-programmable drug delivery systems for musculoskeletal therapy
2004
Giavaresi, G; Tschon, M; Borsari, V; Daly, Jh; Liggat, Jj; Fini, M; Bonazzi, V; Nicolini, Andrea; Carpi, Angelo; Morra, M; Cassinelli, C; Giardino, R....espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/181646
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact