A new probe based on the measurement of electrical impedance has been developed to measure solid/liquid hold-up in stirred tank reactors working with high solid concentration. The main advantage of the probe is that it is fairly non-intrusive and can be used for both laboratory-scale and industrial stirred tank reactors. The relationship between impedance and liquid hold-up closely follows the predictions estimated with the Bruggeman's model. The solid concentration was measured in a 0.5-m diameter vessel mechanically stirred with a Lightnin A310 impeller, set at an off-bottom clearance C = 0.25T. Three sizes of Lightnin A310 impeller were used corresponding to impeller to tank diameter ratios of D/T = 0.346, 0.386 and 0.5. The liquid phase was tap water, whereas two different sets of spherical glass beads (of density ρs = 2500 kg/m3) with narrow size distributions and mean diameters dp = 90 and 600 μm, respectively, were used as solid phase. Solid loads up to 40% by weight were investigated. In addition to solid concentration, power consumption was measured by means of strain gauge technique, and interface height was determined. Preliminary results show that dimensionless axial dispersion coefficient, Des/ND2 , decreases with increasing solid load.
An impedance probe for the measurements of flow characteristics and mixing properties in stirred slurry reactors
BRUNAZZI, ELISABETTA;GALLETTI, CHIARA;PINTUS, SANDRO
2004-01-01
Abstract
A new probe based on the measurement of electrical impedance has been developed to measure solid/liquid hold-up in stirred tank reactors working with high solid concentration. The main advantage of the probe is that it is fairly non-intrusive and can be used for both laboratory-scale and industrial stirred tank reactors. The relationship between impedance and liquid hold-up closely follows the predictions estimated with the Bruggeman's model. The solid concentration was measured in a 0.5-m diameter vessel mechanically stirred with a Lightnin A310 impeller, set at an off-bottom clearance C = 0.25T. Three sizes of Lightnin A310 impeller were used corresponding to impeller to tank diameter ratios of D/T = 0.346, 0.386 and 0.5. The liquid phase was tap water, whereas two different sets of spherical glass beads (of density ρs = 2500 kg/m3) with narrow size distributions and mean diameters dp = 90 and 600 μm, respectively, were used as solid phase. Solid loads up to 40% by weight were investigated. In addition to solid concentration, power consumption was measured by means of strain gauge technique, and interface height was determined. Preliminary results show that dimensionless axial dispersion coefficient, Des/ND2 , decreases with increasing solid load.File | Dimensione | Formato | |
---|---|---|---|
Cherd2004_SL2.pdf
solo utenti autorizzati
Tipologia:
Versione finale editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
384.42 kB
Formato
Adobe PDF
|
384.42 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.