The work presented here was developed in the framework of the SENTINEL Project and is devoted to the analysis of dental radiology dosimetric data. The procedure of data processing allows the analysis of some important aspects related to the protection of the patient and the staff because of the position of the operators near the patient and their exposure to the radiation scattered by the patient. Dental radiology data was collected in an Italian hospital. Following the Italian quality assurance (QA) protocols and suggestions by the leaders of the SENTINEL Project, X-ray equipment performances have been analysed in terms of: kVp accuracy, exposure time accuracy and precision, tube output, dose reproducibility and linearity, beam collimation, artefacts and light tightness. Referring to these parameters the physical quality index (QI) was analysed. In a single numerical value between 0 and 1, QI summarises the results of quality tests for radiological devices. The actual impact of such figure (as suggested by international QA protocols or as adopted by local QA routine) on the policy of machine maintenance and replacement is discussed.

Dental radiology dosimetric data as routinely collected in an Italian hospital

DEL GUERRA, ALBERTO;FANTACCI, MARIA EVELINA;
2008-01-01

Abstract

The work presented here was developed in the framework of the SENTINEL Project and is devoted to the analysis of dental radiology dosimetric data. The procedure of data processing allows the analysis of some important aspects related to the protection of the patient and the staff because of the position of the operators near the patient and their exposure to the radiation scattered by the patient. Dental radiology data was collected in an Italian hospital. Following the Italian quality assurance (QA) protocols and suggestions by the leaders of the SENTINEL Project, X-ray equipment performances have been analysed in terms of: kVp accuracy, exposure time accuracy and precision, tube output, dose reproducibility and linearity, beam collimation, artefacts and light tightness. Referring to these parameters the physical quality index (QI) was analysed. In a single numerical value between 0 and 1, QI summarises the results of quality tests for radiological devices. The actual impact of such figure (as suggested by international QA protocols or as adopted by local QA routine) on the policy of machine maintenance and replacement is discussed.
2008
Fogli, J; Carpentieri, C; DEL GUERRA, Alberto; Fantacci, MARIA EVELINA; Marchi, A; Marzulli, V; Tofani, A.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/196625
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact