Abstract Amyotrophic lateral sclerosis is characterized by degeneration of upper and lower motor neurons. Diffusion tensor imaging (DTI) indexes obtained along the corticospinal tracts distinguish ALS patients and control subjects. Diffusion tensor imaging can be estimated from at least 6 diffusion-weighted images; however an acquisition scheme with a higher number of diffusion directions allows a more robust estimation of DTI indexes. The aim of the study was to establish if a higher number of diffusion encoding gradients increases the diagnostic accuracy of DTI in ALS. We studied 18 patients and 16 control subjects acquiring 2 DTI data sets with 6 and 31 gradient orientations. The mean diffusivity and fractional anisotropy values were measured along the corticospinal tract. Mean diffusivity in ALS was significantly increased (P = 0.026) with respect to control subjects in acquisition scheme with 31 but not (P = 0.214) with 6 diffusion-weighting directions. Fractional anisotropy was significantly lower in patients both with 6 (P = 0.0036) and with 31 (P = 0.0004) diffusion-weighting directions (0.538 vs 0.588 and 0.530 vs 0.594). Fractional anisotropy receiver operating characteristic curve analysis showed a higher diagnostic accuracy by using 31 diffusion-weighting direction (85.76%) with respect to 6 directions (79.86%). Diffusion tensor imaging confirms its potentials in diagnosing ALS with a good accuracy; the acquisition scheme with a higher diffusion-weighting directions seems to better discriminate between ALS patients and control subjects.

Evaluation of corticospinal tract impairment in the brain of patients with amyotrophic lateral sclerosis by using diffusion tensor imaging acquisition schemes with different numbers of diffusion-weighting directions

COSOTTINI, MIRCO;SICILIANO, GABRIELE
2010-01-01

Abstract

Abstract Amyotrophic lateral sclerosis is characterized by degeneration of upper and lower motor neurons. Diffusion tensor imaging (DTI) indexes obtained along the corticospinal tracts distinguish ALS patients and control subjects. Diffusion tensor imaging can be estimated from at least 6 diffusion-weighted images; however an acquisition scheme with a higher number of diffusion directions allows a more robust estimation of DTI indexes. The aim of the study was to establish if a higher number of diffusion encoding gradients increases the diagnostic accuracy of DTI in ALS. We studied 18 patients and 16 control subjects acquiring 2 DTI data sets with 6 and 31 gradient orientations. The mean diffusivity and fractional anisotropy values were measured along the corticospinal tract. Mean diffusivity in ALS was significantly increased (P = 0.026) with respect to control subjects in acquisition scheme with 31 but not (P = 0.214) with 6 diffusion-weighting directions. Fractional anisotropy was significantly lower in patients both with 6 (P = 0.0036) and with 31 (P = 0.0004) diffusion-weighting directions (0.538 vs 0.588 and 0.530 vs 0.594). Fractional anisotropy receiver operating characteristic curve analysis showed a higher diagnostic accuracy by using 31 diffusion-weighting direction (85.76%) with respect to 6 directions (79.86%). Diffusion tensor imaging confirms its potentials in diagnosing ALS with a good accuracy; the acquisition scheme with a higher diffusion-weighting directions seems to better discriminate between ALS patients and control subjects.
2010
Cosottini, Mirco; Giannelli, M; Vannozzi, F; Pesaresi, I; Piazza, S; Belmonte, G; Siciliano, Gabriele
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/201178
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 20
  • ???jsp.display-item.citation.isi??? ND
social impact