The objective of this study was to evaluate the capability and accuracy of MRI with hyperpolarized [1-13C] –pyruvate with using the fast three-dimensional pulse sequence to detect the presence and the regional distribution of transient cardiac metabolic changes in a pig model of ischemia/reperfusion. In 7 male pigs a pneumatic coronary occluder was placed around the left anterior descending coronary. [1-13C]pyruvate polarization was performed using DNP as previously described (1). Injections were performed at rest, during coronary occlusion, and during reperfusion. A 3D-IDEAL spiral sequence was used at 3T MRI scanner (2). Metabolite signal was evaluated in 120 myocardial sectors. The Metabolic Activity Mismatch (MAM) between two segmental variation maps was defined as 100(Sai−Sbi)/(Sai+Sbi)/2, where Sai and Sbi are the relative values of the signal of metabolite in the segment “i” in condition “a” and “b”. The MAM of lactate and bicarbonate of the ischemic segments (middle and apical anteroseptal and anterior segments) were significantly different from the remote regions. In reperfusion a significant inhomogeneity of MAM of bicarbonate (P<0.001) was found, whereas, no significant difference was found for lactate. Figure 2 shows a different distribution for either lactate (−21±6 vs 3±5, P<0.001) or bicarbonate metabolic activity (−29±7 vs 33±6, P<0.0001) in LV segments involved by ischemic process than in remote segments. In reperfusion, lactate signal increased (20±10 vs −7±5, P= 0.007) and bicarbonate decreased (−38±12 vs 36±11, P<0.0001) in involved segments. We evaluated cardiac metabolism in vivo during ischemia and acute reperfusion with a whole heart acquisition using volume coils and with high spatial resolution acquisition. Neither of these requirements was met by previously described methods. The main finding of the current study was the demonstration that spatial resolution obtained using a 3D-IDEAL Spiral CSI pulse sequence was high enough to provide three-dimensional information of acute changes of pyruvate and metabolites in left ventricular myocardium using the conventional regional segmentation. The IDEAL spiral CSI pulse sequence permits to get the complete 3D-dataset of information, with optimal signal to noise ratio and with short acquisition time, for each metabolites simultaneously. This might be potentially relevant for the application of hyperpolarized [1-13C]-pyruvate in human allowing complete acquisition during one breath-hold, increasing the SNR and minimizing the effect of the main limitation of this technique which the fast signal decay of hyperpolarized substrates

3D CMR Mapping of Metabolism by Hyperpolarized 13C-Pyruvate in Ischemia-Reperfusion

Aquaro, GD;Positano, V;Santarelli, MF;Romano, SL;Giovannetti, G;Landini, L;
2013-01-01

Abstract

The objective of this study was to evaluate the capability and accuracy of MRI with hyperpolarized [1-13C] –pyruvate with using the fast three-dimensional pulse sequence to detect the presence and the regional distribution of transient cardiac metabolic changes in a pig model of ischemia/reperfusion. In 7 male pigs a pneumatic coronary occluder was placed around the left anterior descending coronary. [1-13C]pyruvate polarization was performed using DNP as previously described (1). Injections were performed at rest, during coronary occlusion, and during reperfusion. A 3D-IDEAL spiral sequence was used at 3T MRI scanner (2). Metabolite signal was evaluated in 120 myocardial sectors. The Metabolic Activity Mismatch (MAM) between two segmental variation maps was defined as 100(Sai−Sbi)/(Sai+Sbi)/2, where Sai and Sbi are the relative values of the signal of metabolite in the segment “i” in condition “a” and “b”. The MAM of lactate and bicarbonate of the ischemic segments (middle and apical anteroseptal and anterior segments) were significantly different from the remote regions. In reperfusion a significant inhomogeneity of MAM of bicarbonate (P<0.001) was found, whereas, no significant difference was found for lactate. Figure 2 shows a different distribution for either lactate (−21±6 vs 3±5, P<0.001) or bicarbonate metabolic activity (−29±7 vs 33±6, P<0.0001) in LV segments involved by ischemic process than in remote segments. In reperfusion, lactate signal increased (20±10 vs −7±5, P= 0.007) and bicarbonate decreased (−38±12 vs 36±11, P<0.0001) in involved segments. We evaluated cardiac metabolism in vivo during ischemia and acute reperfusion with a whole heart acquisition using volume coils and with high spatial resolution acquisition. Neither of these requirements was met by previously described methods. The main finding of the current study was the demonstration that spatial resolution obtained using a 3D-IDEAL Spiral CSI pulse sequence was high enough to provide three-dimensional information of acute changes of pyruvate and metabolites in left ventricular myocardium using the conventional regional segmentation. The IDEAL spiral CSI pulse sequence permits to get the complete 3D-dataset of information, with optimal signal to noise ratio and with short acquisition time, for each metabolites simultaneously. This might be potentially relevant for the application of hyperpolarized [1-13C]-pyruvate in human allowing complete acquisition during one breath-hold, increasing the SNR and minimizing the effect of the main limitation of this technique which the fast signal decay of hyperpolarized substrates
2013
Aquaro, Gd; Frijia, F; Positano, V; Menichetti, L; Santarelli, Mf; Ardenkjaer-Larsen, Jh; Wiesinger, F; Lionetti, V; Romano, Sl; Bianchi, G; Neglia, D...espandi
File in questo prodotto:
File Dimensione Formato  
Aquaro1.pdf

solo utenti autorizzati

Descrizione: Articolo principale
Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 119.1 kB
Formato Adobe PDF
119.1 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Aquaro.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Documento in Post-print
Licenza: Creative commons
Dimensione 288.7 kB
Formato Adobe PDF
288.7 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/444472
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 15
social impact