Positron emission tomography (PET) is a valuable technique to monitor in situ and non-invasively the particle range in ion beam therapy exploiting the beta+ activity produced in nuclear interactions along the beam path within the target volume. Due to the high random rates and dead-time losses induced by the particle spills, as of to date data are usually acquired during beam pauses or after the irradiation. We have developed a new PET prototype with a faster photon discrimination component that reduces the front-end dead time, and a modularized acquisition system that parallelizes the sensitive detector area, so as to enable data acquisition also during therapeutic irradiation (full in-beam measurement). The PET system has been able to sustain the single photon count rates and acquire coincidences during the beam, in conditions of sub-clinical beam currents. A study on the paralyzation conditions and dead time losses under different beam currents is presented and the feasibility of a full in-beam PET scanner is discussed.

Full in-beam PET measurements of 62 MeV protons onto a PMMA target

SPORTELLI, GIANCARLO;ATTANASI, FRANCESCA;BELCARI, NICOLA;CAMARLINGHI, NICCOLO';ROSSO, VALERIA;DEL GUERRA, ALBERTO
2013-01-01

Abstract

Positron emission tomography (PET) is a valuable technique to monitor in situ and non-invasively the particle range in ion beam therapy exploiting the beta+ activity produced in nuclear interactions along the beam path within the target volume. Due to the high random rates and dead-time losses induced by the particle spills, as of to date data are usually acquired during beam pauses or after the irradiation. We have developed a new PET prototype with a faster photon discrimination component that reduces the front-end dead time, and a modularized acquisition system that parallelizes the sensitive detector area, so as to enable data acquisition also during therapeutic irradiation (full in-beam measurement). The PET system has been able to sustain the single photon count rates and acquire coincidences during the beam, in conditions of sub-clinical beam currents. A study on the paralyzation conditions and dead time losses under different beam currents is presented and the feasibility of a full in-beam PET scanner is discussed.
2013
Sportelli, Giancarlo; K., Straub; M., Aiello; Attanasi, Francesca; Belcari, Nicola; Camarlinghi, Niccolo'; G. A. P., Cirrone; G., Cuttone; S., Ferretti; N., Marino; D., Nicolosi; F., Romano; Rosso, Valeria; DEL GUERRA, Alberto
File in questo prodotto:
File Dimensione Formato  
81/78616369728961282606274847673753720297

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 332.17 kB
Formato Adobe PDF
332.17 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/501272
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact