The cryostat is one of the most important components of the ITER reactor because it provides a vacuum environment limiting the convective heat exchange between the components, especially the magnets. That's why it is designed to withstand negative pressure loads.In this paper a postulated breach of the cryostat boundary leading accident conditions involving the ingress of air into the ITER cryostat has been analyzed with ANSYSCFX. In the performed fluid-dynamic simulations suitable geometry, materials properties and initial and boundary conditions, thoroughly discussed, have been used.The main results indicated that the cryostat, even in the worst condition, seemed to withstand well LOVA without any relevant mechanical failure. The maximum pressure value resulted below the design limit pressure for the cryostat of 0.2. MPa for this accident. Finally it is worthy to remark that these results will be used for a further in depth evaluation of the structural performances of the cryostat itself.

Fluid dynamics analysis of loss of vacuum accident of ITER cryostat

LO FRANO, ROSA
Primo
Writing – Original Draft Preparation
;
AQUARO, DONATO
Supervision
;
2016-01-01

Abstract

The cryostat is one of the most important components of the ITER reactor because it provides a vacuum environment limiting the convective heat exchange between the components, especially the magnets. That's why it is designed to withstand negative pressure loads.In this paper a postulated breach of the cryostat boundary leading accident conditions involving the ingress of air into the ITER cryostat has been analyzed with ANSYSCFX. In the performed fluid-dynamic simulations suitable geometry, materials properties and initial and boundary conditions, thoroughly discussed, have been used.The main results indicated that the cryostat, even in the worst condition, seemed to withstand well LOVA without any relevant mechanical failure. The maximum pressure value resulted below the design limit pressure for the cryostat of 0.2. MPa for this accident. Finally it is worthy to remark that these results will be used for a further in depth evaluation of the structural performances of the cryostat itself.
2016
LO FRANO, Rosa; Aquaro, Donato; Olivi, Nicola
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/833030
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 13
social impact