This study describes an actuated bioreactor which mimics the pulsatile contractile motion of the intestinal barrier using electro-responsive elastomers as smart materials that undergo deformation upon electrical stimulation. The device consists of an annular dielectric elastomer actuator working as a radial artificial muscle able to rhythmically contract and relax a central cell culture well. The bioreactor maintained up to 4 h of actuation at a frequency of 0.15 Hz and a strain of 8%-10%, to those of the cyclic contraction and relaxation of the small intestine. In vitro tests demonstrated that the device was biocompatible and cell-adhesive for Caco-2 cells, which formed a confluent monolayer following 21 days of culture in the central well. In addition, cellular adhesion and cohesion were maintained after 4 h of continuous cyclic strain. These preliminary results encourage further investigations on the use of dielectric elastomer actuation as a versatile technology that might overcome the limitations of commercially available pneumatic driving systems to obtain bioreactors that can cyclically deform cell cultures in a biomimetic fashion.

A bioreactor with an electro-responsive elastomeric membrane for mimicking intestinal peristalsis

AHLUWALIA, ARTI DEVI
2017-01-01

Abstract

This study describes an actuated bioreactor which mimics the pulsatile contractile motion of the intestinal barrier using electro-responsive elastomers as smart materials that undergo deformation upon electrical stimulation. The device consists of an annular dielectric elastomer actuator working as a radial artificial muscle able to rhythmically contract and relax a central cell culture well. The bioreactor maintained up to 4 h of actuation at a frequency of 0.15 Hz and a strain of 8%-10%, to those of the cyclic contraction and relaxation of the small intestine. In vitro tests demonstrated that the device was biocompatible and cell-adhesive for Caco-2 cells, which formed a confluent monolayer following 21 days of culture in the central well. In addition, cellular adhesion and cohesion were maintained after 4 h of continuous cyclic strain. These preliminary results encourage further investigations on the use of dielectric elastomer actuation as a versatile technology that might overcome the limitations of commercially available pneumatic driving systems to obtain bioreactors that can cyclically deform cell cultures in a biomimetic fashion.
2017
Cei, Daniele; Costa, Joana; Gori, Giulia; Frediani, Gabriele; Domenici, Claudio; Carpi, Federico; Ahluwalia, ARTI DEVI
File in questo prodotto:
File Dimensione Formato  
CEI_A bioreactor with an electroresponsive.pdf

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: Importato da Ugov Ricerca - Accesso privato/ristretto
Dimensione 1.56 MB
Formato Adobe PDF
1.56 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/837081
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 19
social impact