Given the critical role of liver mechanics in regulating cell response and directing the development of tissue fibrosis, accurately characterising its mechanical behaviour is of relevance for both diagnostic purposes as well as for tissue engineering and for the development of in-vitro models. Determining and quantifying the mechanical behaviour of soft biological tissues is, however, highly challenging due to their intrinsic labile nature. Indeed, a unique set of values of liver mechanical properties is still lacking to date; testing conditions can significantly affect sample status and hence the measured behaviour and reported results are strongly dependent on the adopted testing method and configuration as well as sample type and status. This review aims at summarising the bulk mechanical properties of liver described in the literature, discussing the possible sources of variation and their implications on the reported results. We distinguish between the intrinsic mechanical behaviour of hepatic tissue, which depends on sample variables, and the measured mechanical properties which also depend on the testing and analysis methods. Finally, the review provides guidelines on tissue preparation and testing conditions for generating reproducible data which can be meaningfully compared across laboratories. Statement of Significance Soft tissue mechanics is widely investigated, but poorly understood. This review identifies and discusses sample and testing variables which can influence the mechanical behaviour of hepatic tissue and consequently the measured mechanical properties. To encourage the biomaterial community towards more standardized testing of soft tissues and enable comparisons between data from different laboratories, we have established new testing methods and experimental recommendations for sample preparation and testing. The review could be of wide interest to scientists involved in biomaterials research because it addresses and proposes guidelines for several issues related to the mechanical testing of soft tissues whose implications have not been considered together before.

Sample, testing and analysis variables affecting liver mechanical properties: A review

MATTEI, GIORGIO
Primo
;
AHLUWALIA, ARTI DEVI
Ultimo
2016-01-01

Abstract

Given the critical role of liver mechanics in regulating cell response and directing the development of tissue fibrosis, accurately characterising its mechanical behaviour is of relevance for both diagnostic purposes as well as for tissue engineering and for the development of in-vitro models. Determining and quantifying the mechanical behaviour of soft biological tissues is, however, highly challenging due to their intrinsic labile nature. Indeed, a unique set of values of liver mechanical properties is still lacking to date; testing conditions can significantly affect sample status and hence the measured behaviour and reported results are strongly dependent on the adopted testing method and configuration as well as sample type and status. This review aims at summarising the bulk mechanical properties of liver described in the literature, discussing the possible sources of variation and their implications on the reported results. We distinguish between the intrinsic mechanical behaviour of hepatic tissue, which depends on sample variables, and the measured mechanical properties which also depend on the testing and analysis methods. Finally, the review provides guidelines on tissue preparation and testing conditions for generating reproducible data which can be meaningfully compared across laboratories. Statement of Significance Soft tissue mechanics is widely investigated, but poorly understood. This review identifies and discusses sample and testing variables which can influence the mechanical behaviour of hepatic tissue and consequently the measured mechanical properties. To encourage the biomaterial community towards more standardized testing of soft tissues and enable comparisons between data from different laboratories, we have established new testing methods and experimental recommendations for sample preparation and testing. The review could be of wide interest to scientists involved in biomaterials research because it addresses and proposes guidelines for several issues related to the mechanical testing of soft tissues whose implications have not been considered together before.
2016
Mattei, Giorgio; Ahluwalia, ARTI DEVI
File in questo prodotto:
File Dimensione Formato  
MATTEI-Sample, testing and analysis review.pdf

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: Importato da Ugov Ricerca - Accesso privato/ristretto
Dimensione 1.03 MB
Formato Adobe PDF
1.03 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/837104
Citazioni
  • ???jsp.display-item.citation.pmc??? 18
  • Scopus 58
  • ???jsp.display-item.citation.isi??? 53
social impact