Aims/hypothesis Elevated 2-h plasma glucose concentration (2 h-PG) during a 75 g OGTT predict the development of type 2 diabetes mellitus. However, 1-h plasma glucose concentration (1 h-PG) is associated with insulin secretion and may be a better predictor of type 2 diabetes. We aimed to investigate the association between 1 h-PG and 2 h-PG using gold standard methods for measuring insulin secretion and action. We also compared 1 h-PG and 2 h-PG as predictors of type 2 diabetes mellitus. Methods This analysis included adult volunteers without diabetes, predominantly Native Americans of Southwestern heritage, who were involved in a longitudinal epidemiological study from 1965 to 2007, with a baseline OGTT that included measurement of 1 h-PG. Group 1 (n = 716) underwent an IVGTT and hyperinsulinaemic-euglycaemic clamp for measurement of acute insulin response (AIR) and insulin-stimulated glucose disposal (M), respectively. Some members of Group 1 (n = 490 of 716) and members of a second, larger, group (Group 2; n = 1946) were followed-up to assess the development of type 2 diabetes (median 9.0 and 12.8 years follow-up, respectively). Results Compared with 2 h-PG (r = -0.281), 1 h-PG (r = -0.384) was more closely associated with AIR, whereas, compared with 1 h-PG (r = -0.340), 2 h-PG (r = -0.408) was more closely associated with M. Measures of 1 h-PG and 2 h-PG had similar abilities to predict type 2 diabetes, which did not change when both were included in the model. A 1 h-PG cut-off of 9.3 mmol/l provided similar levels of sensitivity and specificity as a 2 h-PG cut-off of 7.8 mmol/l; the latter is used to define impaired glucose tolerance, a recognised predictor of type 2 diabetes mellitus. Conclusions/interpretation The 1 h-PG was associated with important physiological predictors of type 2 diabetes and was as effective as 2 h-PG for predicting type 2 diabetes mellitus. The 1 h-PG is, therefore, an alternative method of identifying individuals with an elevated risk of type 2 diabetes mellitus.

One-hour and two-hour postload plasma glucose concentrations are comparable predictors of type 2 diabetes mellitus in Southwestern Native Americans

Piaggi P;
2017-01-01

Abstract

Aims/hypothesis Elevated 2-h plasma glucose concentration (2 h-PG) during a 75 g OGTT predict the development of type 2 diabetes mellitus. However, 1-h plasma glucose concentration (1 h-PG) is associated with insulin secretion and may be a better predictor of type 2 diabetes. We aimed to investigate the association between 1 h-PG and 2 h-PG using gold standard methods for measuring insulin secretion and action. We also compared 1 h-PG and 2 h-PG as predictors of type 2 diabetes mellitus. Methods This analysis included adult volunteers without diabetes, predominantly Native Americans of Southwestern heritage, who were involved in a longitudinal epidemiological study from 1965 to 2007, with a baseline OGTT that included measurement of 1 h-PG. Group 1 (n = 716) underwent an IVGTT and hyperinsulinaemic-euglycaemic clamp for measurement of acute insulin response (AIR) and insulin-stimulated glucose disposal (M), respectively. Some members of Group 1 (n = 490 of 716) and members of a second, larger, group (Group 2; n = 1946) were followed-up to assess the development of type 2 diabetes (median 9.0 and 12.8 years follow-up, respectively). Results Compared with 2 h-PG (r = -0.281), 1 h-PG (r = -0.384) was more closely associated with AIR, whereas, compared with 1 h-PG (r = -0.340), 2 h-PG (r = -0.408) was more closely associated with M. Measures of 1 h-PG and 2 h-PG had similar abilities to predict type 2 diabetes, which did not change when both were included in the model. A 1 h-PG cut-off of 9.3 mmol/l provided similar levels of sensitivity and specificity as a 2 h-PG cut-off of 7.8 mmol/l; the latter is used to define impaired glucose tolerance, a recognised predictor of type 2 diabetes mellitus. Conclusions/interpretation The 1 h-PG was associated with important physiological predictors of type 2 diabetes and was as effective as 2 h-PG for predicting type 2 diabetes mellitus. The 1 h-PG is, therefore, an alternative method of identifying individuals with an elevated risk of type 2 diabetes mellitus.
2017
Paddock, E; Hohenadel, Mg; Piaggi, P; Vijayakumar, P; Hanson, Rl; Knowler, Wc; Krakoff, J; Chang, Dc
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/925474
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 35
social impact